Fixes are available
APAR status
Closed as program error.
Error description
The following code replicates the exception when generating to COBOL: Program Wp9lCreateSjobForEmbdelivery type basicProgram() { } function main() wp9lCreateSjobForEmbdeliveryMain(); end function wp9lCreateSjobForEmbdeliveryMain() nullable_realLoadingDay1 char(1)?; open countEmballageDeliveryCur1 into nullable_realLoadingDay1 with #sql{ select REAL_LOADING_DAY from EMBDEL }; get next from countEmballageDeliveryCur1; // Altering the above to the following enables successful generation // get next from countEmballageDeliveryCur1 into nullable_realLoadingDay1; end end Example output: IWN.VAL.9994.i 1/1 Generating part getError.Wp9lCreateSjobForEmbdelivery with build descriptor EGLProgramsCOBOLBuildOptions from file \EGLPrograms\EGLSource\EGLPrograms.eglbld. IWN.VAL.9999.e 0/0 Stack Trace: java.lang.NullPointerException IWN.VAL.9999.e 0/0 Stack Trace: at com.ibm.etools.egl.generation.cobol.analyzers.language.postanaly sis.sqlio.SqlGetByPositionStatementPostAnalyzer.<init>(SqlGetByP ositionStatementPostAnalyzer.java:76)
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users that are doing a SQL get next statement without either * * a target record or an into clause can get a null pointer * * exception * **************************************************************** * PROBLEM DESCRIPTION: * * A null pointer exception in * * SqlGetByPositionStatementPostAnalyzer can occur. A * * workaround is to add either a target record or an into * * clause for the SQL statement, or to apply the fixtest. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The problem is fixed.
Temporary fix
Comments
APAR Information
APAR number
PI26965
Reported component name
RATL BUS DEV
Reported component ID
5724S5000
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-10-03
Closed date
2014-12-15
Last modified date
2014-12-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL BUS DEV
Fixed component ID
5724S5000
Applicable component levels
R901 PSY
UP
R911 PSY
UP