A fix is available
APAR status
Closed as program error.
Error description
In Worklight Studio 6.2, if you open Worklight Development Server's server.xml file, look for the existing <logging consoleLogLevel="AUDIT" copySystemStreams="false"/> entry, then modify it to use a custom setting, for example consoleLogLevel="INFO", then restart Worklight Studio. When Worklight Studio has completed restarting, if you navigate to server.xml file again, you fill find an extra <logging> line to the end of the server.xml file: <logging consoleLogLevel="AUDIT" copySystemStreams="false"/> Since this line comes later in the file, it takes precedence over the first line for the server, causing your custom setting to be ignored.
Local fix
A workaround is to not remove the appended element and to reverse both the <logging> elements order so that the customer's one is taken into account.
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Worklight Studio that want to change the logging * * level * **************************************************************** * PROBLEM DESCRIPTION: * * See error description. * **************************************************************** * RECOMMENDATION: * * - * ****************************************************************
Problem conclusion
The code was changed to fix the problem.
Temporary fix
Comments
APAR Information
APAR number
PI24870
Reported component name
WORKLIGHT CONSU
Reported component ID
5725I4301
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-08-29
Closed date
2014-11-04
Last modified date
2014-11-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WORKLIGHT CONSU
Fixed component ID
5725I4301
Applicable component levels
R620 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSZH4A","label":"IBM Worklight"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: