IBM Support

PI23170: UNDEFINED IDENTIFIER IN DFSKNUC0 AFTER PI19255 14/08/19 PTF PEREMOVE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PI19255 Removed unused variables from macro DFSKVARS but one
    these variables was not deleted from DFSKNUC0.  This caused an
    undeclared identifier error during compile of DFSKNUC0.
    

Local fix

  • No Local Fix.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IMS V12 users of system utility DFSURCM0 *
    ****************************************************************
    * PROBLEM DESCRIPTION: AKEE34012I PLX compiler error after     *
    *                      APPLY'ing PI19255.                      *
    ****************************************************************
    * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF      *
    ****************************************************************
    PI19255 removed unused variables from macro DFSKVARS but one
    variable was still referenced, although unused in DFSKNUC0.
    DFSKNUC0 is called by DFSURCM0.  The reference to the unused
    variable results in a AKEE34012I compiler error.
    

Problem conclusion

  • GEN:
    KEYWORDS:
    
    *** END IMS KEYWORDS ***
    The reference to the unused variable is removed from DFSKNUC0.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI23170

  • Reported component name

    IMS V12

  • Reported component ID

    5635A0300

  • Reported release

    200

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-08-01

  • Closed date

    2014-09-08

  • Last modified date

    2014-10-02

  • APAR is sysrouted FROM one or more of the following:

    PI23165

  • APAR is sysrouted TO one or more of the following:

    UI21159

Modules/Macros

  •    DFSKNUC0
    

Fix information

  • Fixed component name

    IMS V12

  • Fixed component ID

    5635A0300

Applicable component levels

  • R200 PSY UI21159

       UP14/09/09 P F409

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.