Error description

  • Binder message IEW2470E is issued when SMP/E APPLYing PRF "B"
    usermod (for example IRT121B ) processing modules IRTPRE00,
    IRTRCC00 and IRTXRI09 - IRTXRI13.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users of Program Restart Facility V2R2   *
    ****************************************************************
    * PROBLEM DESCRIPTION: When applying B Usermods, for example   *
    *                      IRT131B, several occurrences of Linkage *
    *                      Editor messages IEW2470E and IEW2457E   *
    *                      result. These are caused by             *
    *                      linkage editor control statements that  *
    *                      refer to external entry points that     *
    *                      are not needed by or are missing from   *
    *                      the module being constructed.           *
    *                                                              *
    *                      JCLIN member H23D220 had the same       *
    *                      issue so it is also updated.            *
    *                                                              *
    *                      Several source modules had missing or   *
    *                      incorrect comments, so those are also   *
    *                      changed with this APAR.                 *
    ****************************************************************
    * RECOMMENDATION: Apply this service, then, if an IRTxxxB      *
    *                 Usermod was previously installed, re-install *
    *                 the IRTxxxB Usermod provided in this APAR.   *
    *                 Refer to the section in the User Guide       *
    *                 entitled, Copying IMS Program Restart        *
    *                 Facility Load Modules.                       *
    ****************************************************************
    B usermods and JCLIN are changed to reflect correct module
    construction. Comments in corressponding source modules are
    corrected.
    

Problem conclusion

  • Apply this service, then, if an IRTxxxB Usermod was previously
    installed, re-install the IRTxxxB Usermod provided in this
    APAR. Refer to the section in the User Guide entitled,
    Copying IMS Program Restart Facility Load Modules.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI22005

  • Reported component name

    IMS PGM RESTART

  • Reported component ID

    5655E1400

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-07-14

  • Closed date

    2014-12-22

  • Last modified date

    2015-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI24095

Modules/Macros

  • H23D220J IRTGQSC0 IRTPRE10 IRTRCC00 IRTXBBO0
    IRT111B  IRT121B  IRT131B  IRT141B
    

Fix information

  • Fixed component name

    IMS PGM RESTART

  • Fixed component ID

    5655E1400

Applicable component levels

  • R220 PSY UI24095

       UP14/12/24 P F412

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
24 January 2022