APAR status
Closed as program error.
Error description
When using the MT102 SWIFT schema in the Message Editor it is not possible to select type 50F for the Ordering Customer field. Types 50A & 50K are available only. WORKAROUND: 1. Delete the existing Ordering Customer field. 2. Right-click on the Common Field Elements node and click Add Child > User Defined > String 3. Name the field "50F"
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration tester who use SWIFT * * messages * **************************************************************** * PROBLEM DESCRIPTION: * * A user is not able to add the 50F option for the "Ordering * * customer" fields in SWIFT MT 101 and MT 102 messages despite * * the SWIFT specification stating that it is a valid option. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
In Rational Integration Tester 8.6.0.1 it is possible to add the 50F option as per the specification.
Temporary fix
Comments
APAR Information
APAR number
PI20576
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
851
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-06-23
Closed date
2014-09-01
Last modified date
2014-09-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSY
UP
Document Information
Modified date:
17 October 2021