IBM Support

PI19125: WMQ Z/OS: ABN=074-00000000

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABN=074-00000000,U=SETUP   -CSQSGSTK,  M=CSQVLFRR
    is occurring when CSQSVSTK has issued a SETLOCK OBTAIN,TYPE=CML
    
    ABEND074 means a program issued the SETLOCK macro and
    supervisor control could not finish processing the macro.
    
    ST REGs and the SYSTRACE show the abend is actually an ABENDAC7
    RSN00440004. Reason 00440004 is because DIAGxx trap
    IEAMISUSEPMC is set to detect the misuse of "Process Must
    Complete". So, if a PAUSE is attempted with PMC set, ABENDAC7
    RSN00440004 is issued. SYSTRACE shows a SCHEDULE from CSQVEUS1
    before the abend SVC D. TCBPMC is no longer set at the time the
    TCB is captured however.
    
    
    Additional Symptom(s) Search Keyword(s):
    ABEND074 ABENDS074 S074 S0074 074
    ABENDAC7 ABENDSAC7 SAC7 S0AC7 AC7
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 *
    *                 Release 1 Modification 0.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABN=074-00000000 for CSQSVSTK.          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    An ABENDS074 occurs after CSQSVSTK has issued a SETLOCK
    OBTAIN for a CML (Cross Memory Lock) while PMC (Process
    Must Complete) is in effect.
    The lock is currently
    held by another process, so a IEAVPSE (Pause) is issued to
    wait for it to become available. However this is an illegal
    command when PMC is set.
    This causes an Abend AC7-00440004. Since the IEAMISUSEPMC
    diag trap was set at the time of the abend, this produced
    the ABENDS074.
    

Problem conclusion

  • CSQVEUS1 has been altered to reset the PMC status before
    releasing the latch.
    100Y
    CSQVEUS1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI19125

  • Reported component name

    WMQ Z/OS V7

  • Reported component ID

    5655R3600

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / CST / Xsystem

  • Submitted date

    2014-06-02

  • Closed date

    2014-09-30

  • Last modified date

    2015-02-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI21889 PI27570

Modules/Macros

  • CSQVEUS1
    

Fix information

  • Fixed component name

    WMQ Z/OS V7

  • Fixed component ID

    5655R3600

Applicable component levels

  • R100 PSY UI21889

       UP14/10/17 P F410

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.