A fix is available
APAR status
Closed as program error.
Error description
ABN=074-00000000,U=SETUP -CSQSGSTK, M=CSQVLFRR is occurring when CSQSVSTK has issued a SETLOCK OBTAIN,TYPE=CML ABEND074 means a program issued the SETLOCK macro and supervisor control could not finish processing the macro. ST REGs and the SYSTRACE show the abend is actually an ABENDAC7 RSN00440004. Reason 00440004 is because DIAGxx trap IEAMISUSEPMC is set to detect the misuse of "Process Must Complete". So, if a PAUSE is attempted with PMC set, ABENDAC7 RSN00440004 is issued. SYSTRACE shows a SCHEDULE from CSQVEUS1 before the abend SVC D. TCBPMC is no longer set at the time the TCB is captured however. Additional Symptom(s) Search Keyword(s): ABEND074 ABENDS074 S074 S0074 074 ABENDAC7 ABENDSAC7 SAC7 S0AC7 AC7
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of WebSphere MQ for z/OS Version 7 * * Release 1 Modification 0. * **************************************************************** * PROBLEM DESCRIPTION: ABN=074-00000000 for CSQSVSTK. * **************************************************************** * RECOMMENDATION: * **************************************************************** An ABENDS074 occurs after CSQSVSTK has issued a SETLOCK OBTAIN for a CML (Cross Memory Lock) while PMC (Process Must Complete) is in effect. The lock is currently held by another process, so a IEAVPSE (Pause) is issued to wait for it to become available. However this is an illegal command when PMC is set. This causes an Abend AC7-00440004. Since the IEAMISUSEPMC diag trap was set at the time of the abend, this produced the ABENDS074.
Problem conclusion
CSQVEUS1 has been altered to reset the PMC status before releasing the latch. 100Y CSQVEUS1
Temporary fix
Comments
APAR Information
APAR number
PI19125
Reported component name
WMQ Z/OS V7
Reported component ID
5655R3600
Reported release
100
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / CST / Xsystem
Submitted date
2014-06-02
Closed date
2014-09-30
Last modified date
2015-02-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI21889 PI27570
Modules/Macros
CSQVEUS1
Fix information
Fixed component name
WMQ Z/OS V7
Fixed component ID
5655R3600
Applicable component levels
R100 PSY UI21889
UP14/10/17 P F410
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: