A fix is available
APAR status
Closed as program error.
Error description
MESSAGE DFS3889A SYSTEM DATASETS INCONSISTENT - QBLKS, RC=04 When doing subsystem cloning while IMS is active, the target IMS can not be emergency restarted without COLDSYS option. This means that some updates may be left as inflight. The error message received if just '/ERE.' restart command is used is:DFS3889A SYSTEM DATASETS INCONSISTENT - QBLKS, RC=04
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of GCL 1.2 * **************************************************************** * PROBLEM DESCRIPTION: Target IMS subsystem cannot be * * restarted without COLDSYS * **************************************************************** * RECOMMENDATION: * **************************************************************** After subsystem cloning, many libraries require manual intervention to APF authorize.
Problem conclusion
Install the APAR to fix an emergency restart issue and to add ability to dynamically APF authorize libraries
Temporary fix
Comments
APAR Information
APAR number
PI17570
Reported component name
IMS CLONING TOO
Reported component ID
5655U9100
Reported release
120
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2014-05-08
Closed date
2018-09-21
Last modified date
2018-11-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI58359
Modules/Macros
GCL$RAC0 GCL$TDB1 GCLDBRC GCLDYNAL GCLIEBCY GCLIMSA1 GCLIMSB1 GCLIMSC1 GCLIMSD1 GCLIMSE1 GCLIMSF1 GCLINI# GCLITKB GCLIUPDT GCLIUPD2 GCLLITS GCLLOGA1 GCLLOGB1 GCLLOGC1 GCLLOGD1 GCLLOGE1 GCLLOGF1 GCLMSG GCLMSGS GCLONEJB GCLRECA1 GCLRECB1 GCLRECC1 GCLRECD1 GCLRECE1 GCLRECF1 GCLRECON GCLSEQUP GCL00315 GCL0032A GCL0032B GCL0032C GCL00320 GCL00321 GCL00322 GCL00323 GCL00324 GCL00325 GCL00326 GCL00327 GCL00328 GCL00329 GCL2DOUT GCL2GNJC GCL2MAIN HAEQ120J
Fix information
Fixed component name
IMS CLONING TOO
Fixed component ID
5655U9100
Applicable component levels
R120 PSY UI58359
UP18/09/29 P F809
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCBTY5","label":"IMS Cloning Tool"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"1.2.0"}]
Document Information
Modified date: