Error description

  • The count of MQCTLs in SMF 116 records (WTASCTN) is incorrect
    for long-running tasks as the count is not cleared at each SMF
    interval (WTASCTET and WTASCTCT are also incorrect, as are
    WTASTPN, WTASSUN, WTASSQN, WTASSTN).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of WebSphere MQ Version 7          *
    *                 Release 0 Modification 1 and                 *
    *                 Release 1 Modification 0.                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: When class 3 accounting trace is active *
    *                      the invocation counts and times for the *
    *                      new MQ V7 API calls are incorrect in    *
    *                      SMF 116 records for long running        *
    *                      threads.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When collecting class 3 accounting in WTAS records the
    invocation counts and times for the new MQ API calls are not
    cleared after the statistics collection interval (when WTAS is
    copied to SMF116) for long running threads that expand over
    multiple statistics collection intervals.
    
    The following are the counts and times that are affected:
    WTASPBHW Publish high water mark elapsed time
    WTASPBTT Publish total elapsed time
    WTASTPET MQOPEN/MQPUT1 resolving to topics elapsed time
    WTASTPCT MQOPEN/MQPUT1 resolving to topics CPU time
    WTASTPN  MQOPEN/MQPUT1 resolving to topics count
    WTASSUET MQSUB Elapsed time
    WTASSUCT MQSUB CPU time
    WTASSUN  MQSUB count
    WTASSUSC MQSUB count of selectors
    WTASSUSL MQSUB max length selector
    WTASSQET MQSUBRQ Elapsed time
    WTASSQCT MQSUBRQ CPU time
    WTASSQN  MQSUBRQ count
    WTASCTET MQCTL Elapsed time
    WTASCTCT MQCTL CPU time
    WTASCTN  MQCTL count
    WTASSTET MQSTAT Elapsed time
    WTASSTCT MQSTAT CPU time
    WTASSTN  MQSTAT count
    WTASCTSR CPU TIME UNDER SRB
    

Problem conclusion

  • CSQ7PLRT has been updated to clear the WTAS record after every
    statistics collection interval when data is copied to SMF 116
    records.
    010Y
    100Y
    CSQ7PLRT
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI17215

  • Reported component name

    WMQ Z/OS V7

  • Reported component ID

    5655R3600

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-05-05

  • Closed date

    2014-05-16

  • Last modified date

    2014-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI18051 UI18052

Modules/Macros

  • CSQ7PLRT
    

Fix information

  • Fixed component name

    WMQ Z/OS V7

  • Fixed component ID

    5655R3600

Applicable component levels

  • R010 PSY UI18051

       UP14/06/27 P F406

  • R100 PSY UI18052

       UP14/06/27 P F406

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.1","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 July 2014