A fix is available
APAR status
Closed as program error.
Error description
NTH fails to connect to a DB2 subsystem after the subsystem was recycled or restarted. . The OMPE Server STC joblog shows: . KO2O1325E NEAR-TERM HISTORY DATA COLLECTOR - DISCONNECT FROM DB2 FAILED. REASON CODE 00C12824 (CHECKRC )
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - NTH - Near Term History * **************************************************************** * PROBLEM DESCRIPTION: NTH terminates after attempting to * * connect with a DB2 which has been * * started in Maintenance mode. It does * * not reconnect after the DB2 is * * re-started in normal mode. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: NTH terminated after connecting to DB2 in maintenance mode. PROBLEM CONCLUSION: NTH will wait until DB2 is started in normal mode. KEYWORDS: 00C12824 TERMINATE IDENTIFY THREAD DISCONNECT
Problem conclusion
NTH will wait until DB2 is started in normal mode. KEYWORDS: 00C12824 TERMINATE IDENTIFY THREAD DISCONNECT
Temporary fix
Comments
APAR Information
APAR number
PI16191
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-04-16
Closed date
2014-06-18
Last modified date
2014-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI18924 UI18925 UI18926
Modules/Macros
KO2HCAFB
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UI18924
UP14/06/19 P F406
R511 PSY UI18925
UP14/06/19 P F406
R520 PSY UI18926
UP14/06/19 P F406
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: