IBM Support

PI14349: POSSIBLE MESSAGE GCL05647E ANTRQST ERROR: DATA MOVER RETURN CODE=7645 X'1DDD' REASON CODE=4042 X'FA2A' LOC=FW002

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When running COPYCHECK WITHDRAW it is possible to get
    GCL05647E ANTRQST ERROR; DATA MOVER RETURN CODE=7645 X'1DDD'
    REASON CODE=4042 X'FA2A' LOC=FW002
    There is a small window between the check for FlashCopy
    relationships on the volumes and when the FlashCopy WITHDRAW is
    done. If the relationship ends between the check and WITHDRAW
    the above error will be reported.
    The ANTRQST return code 7645 should not cause an error to be
    reported.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Cloning Tool V1.2               *
    ****************************************************************
    * PROBLEM DESCRIPTION: Possible message GCL05647E ANTRQST      *
    *                      ERROR: DATA MOVER RETURN CODE=7645      *
    *                      X'1DDD' REASON CODE=4042 X'FA2A'        *
    *                      LOC=FW002                               *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When running COPYCHECK WITHDRAW it is possible to get
    GCL05647E ANTRQST ERROR; DATA MOVER RETURN CODE=7645 X'1DDD'
    REASON CODE=4042 X'FA2A' LOC=FW002
    There is a small window between the check for FlashCopy
    relationships on the volumes and when the FlashCopy WITHDRAW is
    done. If the relationship ends between the check and WITHDRAW
    the above error will be reported.
    The ANTRQST return code 7645 should not cause an error to be
    reported.
    

Problem conclusion

  • Code has been modified to correct this issue.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI14349

  • Reported component name

    IMS CLONING TOO

  • Reported component ID

    5655U9100

  • Reported release

    120

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-03-24

  • Closed date

    2014-04-01

  • Last modified date

    2014-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI16629

Modules/Macros

  • GCL00056
    

Publications Referenced
SC19247500    

Fix information

  • Fixed component name

    IMS CLONING TOO

  • Fixed component ID

    5655U9100

Applicable component levels

  • R120 PSY UI16629

       UP14/04/04 P F404

Fix is available