A fix is available
APAR status
Closed as program error.
Error description
By default OMPELOG is set active. This results in messages that go to JESMSGLG and messages that go to SYSPRINT being written to the same DD OMPELOG. The timestamps in the OMPELOG are not adjusted for the local system offset to GMT.
Local fix
The OMPELOG can be turned off by setting OMPELOG=INACTIVE in member OMPEOPTS of the RKD2PAR and / or RKD2PARU datasets, which ever is first in the concatenation
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - OMEGAMON collector * **************************************************************** * PROBLEM DESCRIPTION: OMPELOG timestamp is not adjusted to * * local time offset. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: The messages in OMPELOG are prefixed by a date/time string. This string contains the value from the hardware clock. The hardware clock may be set to a value other than local time. PROBLEM CONCLUSION: Adjust the hardware clock value using the local date and time offset. Format the adjusted value for use in the OMPELOG. KEYWORDS: STCK GMT
Problem conclusion
Adjust the hardware clock value using the local date and time offset. Format the adjusted value for use in the OMPELOG. KEYWORDS: STCK GMT
Temporary fix
Comments
APAR Information
APAR number
PI14217
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-03-21
Closed date
2014-06-06
Last modified date
2014-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI18653 UI18654
Modules/Macros
KO2ZLOG
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
01 July 2014