IBM Support

PI14105: PROGRAM RESTART FACILITY ISSUES UNDOCUMENTED MESSAGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR addresses multiple Program Restart Facility error
    conditions.
    1. PRF message IRT087I TOTAL CHKP CALLS: nnn BYPASSED: nnn
       is issued at the end of IMS processing, but this message
       number is incorrect, and neither the correct nor incorrect
       message number is documented in the PRF User's Guide.
    2. When message IRT250E is issued for module IRTRFEnn, PRF
       disables BYPCHKP processing instead of abending.
    3. Batch job ABEND0C4 in IRTRFE12 (or other IRTRFEnn modules).
    keywords:  MSGIRT087I MSGIRT250E
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users of Program Restart Facility V2R2.  *
    ****************************************************************
    * PROBLEM DESCRIPTION: Correct documentation for messages      *
    *                      IRT097I, IRT098I, and IRT250E.          *
    *                                                              *
    *                      Correct ABEND0C4 in IRTRFE12.           *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF that corrects this APAR.       *
    ****************************************************************
    This APAR corrects multiple Program Restart Facility errors:
    
    1.  PRF issues message
    
        IRT087I TOTAL CHKP CALLS: NNN BYPASSED: NNN
    
        at the end of IMS processing, but this message number is
        incorrect, and neither the correct nor incorrect message
        number is documented in the PRF User's Guide.
    
    2.  When message IRT250E is issued by module IRTRFEnn, PRF
        disables BYPCHKP processing instead of abending.
    
    3.  Batch JOB may experience an ABEND0C4 in IRTRFE12 (or other
        IRTRFEnn modules).
    

Problem conclusion

  • 1.  Correct message IRT097I, which was issued as message
        IRT087I, and add the new message to the PRF UsersS Guide.
        Also add related message IRT098I.
    
    2.  Correct the description for message IRT250E to indicate that
        BYPCHKP processing is disabled, but the job continues
        processing.
    
    3.  Correct code to prevent the ABEND0C4 in IRTRFEnn.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI14105

  • Reported component name

    IMS PGM RESTART

  • Reported component ID

    5655E1400

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-03-19

  • Closed date

    2014-06-16

  • Last modified date

    2014-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI18853

Modules/Macros

  • IRTIXT09 IRTIXT10 IRTIXT11 IRTIXT12 IRTIXT13
    IRTRCC00 IRTRFE09 IRTRFE10 IRTRFE11 IRTRFE12 IRTRFE13
    

Publications Referenced
SC19398500    

Fix information

  • Fixed component name

    IMS PGM RESTART

  • Fixed component ID

    5655E1400

Applicable component levels

  • R220 PSY UI18853

       UP14/06/17 P F406

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSAVHR","label":"IMS Program Restart Facility for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"220","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
24 January 2022