A fix is available
APAR status
Closed as program error.
Error description
Rollup (forward fit) of the following V120 maintenance: PI06811 / UI13468 PI07604 / UI13518 PI07609 / UI13657 PI08591 / UI14051 PI08083 / UI15752 PI08199 / UI16461
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of HPFPU Fast Path Advanced * * Tools, HPFPU Fast Path Online Tools, and DB * * Sensor in Fast Path Solution Pack Version 1 * * Release 3 (FMID: HAHQ130). * **************************************************************** * PROBLEM DESCRIPTION: Forward Fit APAR of the following 6 * * FPSP V1R2 APARs; * * - PI06811 * * - PI07604 * * - PI07609 * * - PI08083 * * - PI08199 * * - PI08591 * * * * The following problems are also * * included. * * 1.FPA main task abends with HFPMESTx * * 0C4 when the subtask abends. * * 2.Missing ONLINE POINTER CHECKER * * STATISTICS report in FPXRPTS when * * OPC is performed with SYSIN DD * * 3.Add VSO status to ONLINE POINTER * * CHECKER STATISTICS report. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR. * **************************************************************** Forward Fit APAR of FPSP V1R2 PI06811. 1. Unable to save Sensor Data when exceptions occur with SENSOR_UOW=YES and THRESHOLD is specified due to exit condition. 2. ABEND occurs when SEGLDIST=YES and the DB has ROOT and SDEP segments only. Forward Fit APAR of FPSP V1R2 PI07604. There was a problem that Online Pointer Checker was checking the length of SDEP control segment. Therefore, Online Pointer Checker issued error ONLINE POINTER SCAN REPORT in FPXRPTS DD. Forward Fit APAR of FPSP V1R2 PI07609. The DAR13SO work data set can be allocated dynamically when . FULLSTEP=YES and TYPRUN=PTRALL/RPT are specified for OPC . PTRCHK=YES, FULLSTEP=YES and TYPRUN=PTRALL/RPT are specified for OER However, the estimation for the primary size of the DAR13SO work data set is too small when the average segment length in DBD definition is much larger than the actual average segment length, which caused B37. Forward Fit APAR of FPSP V1R2 PI08083. Running of HFPMAIN0 to unload a DEDB, informational message HFPD0001I is written on two lines to the SYSLOG. The message is incorrectly written with SYSLOG Record type N, which means "single line message". System automation cannot interpret the second line as it determines each line to be a separate message. Forward Fit APAR of FPSP V1R2 PI08199. 1. FPA Analyze function: Even if an incorrect CI RBA value is set at the end of a CI, FPA Analyze function does not report the problem of the incorrect CI RBA value and continues processing with no error. 2. FPO utilities: Even if an incorrect CI RBA value is set at the end of a CI, FPO utilities do not report the problem of the incorrect CI RBA value. Instead, FPO utilities issue FPX0011E message and ends with ABENDU3500. Forward Fit APAR of FPSP V1R2 PI08591. ODE with SDEPHIER=YES option extracted the same SDEP segments twice, when their parent ROOT segment was located in an IOVF CI, and this IOVF CI was re-read for processing of the next ROOT segment. The issues that have been fixed in FPSP V1R2 and are not listed above have been fixed in FPSP V1R3 GA level and PI06716. Problems that are fixed only for FPSP V1R3. 1.HFPMESTx 0C4 abend occurs when main task other than abend occurs. 2.FPXRPTS DD does not output ONLINE POINTER CHECKER STATISTICS report when used DASYSIN DD for OPC. 3.ONLINE POINTER CHECKER STATISTICS report does not output VSO status for OPC or OER.
Problem conclusion
Forward Fit APAR of FPSP V1R2 PI06811. 1. Changed exit condition to store Sensor data even if exception occurs. 2. Modified to take the DB of ROOT and SDEP segments only correctly. Forward Fit APAR of FPSP V1R2 PI07604. When CI has SDEP control segment, checking of SDEP segment length will not be performed. Forward Fit APAR of FPSP V1R2 PI07609. OPC and OER have been modified to adjust the primary and secondary sizes for the work data sets when the calculated primary size is smaller than 1CYLINDER. Forward Fit APAR of FPSP V1R2 PI08083. When a message id has the multiple text lines to SYSLOG, the FPA changes to write them as one multiple-text message. The message ids for abend are still written as a single line message because those line messages have the specific message id. The FPO does not have the multiple text lines to SYSLOG. Forward Fit APAR of FPSP V1R2 PI08199. 1. FPA Analyze function: FPA Analyze function has been modified to check the integrity of the CI RBA value. FPA Analyze function checks the CI RBAs of all CIs including 1st CI and 2nd CI, but except for the CIs in reorg UOW. If an incorrect RBA value is set at the end of a CI, FPA Analyze function issues a message in the Resolve Pointers report, generates a snap dump when CISNAP=YES is specified, and counts as a pointer error. 2. FPO utilities: FPO utilities have been modified to check the integrity of the CI RBA value. If an AO status code is returned when FPO utilities read CIs, FPO utilities issue FPX0011E message and end with ABENDU3500 as before, and also check the integrity of the RBA value of the CI that is failed to read. If an incorrect RBA value is set at the end of a CI, FPO utilities issue FPX0339E message. Forward Fit APAR of FPSP V1R2 PI08591. ODE has been modified not to extract the SDEP segments when an IOVF CI is re-read, where their parent ROOT segment is located. Because these SDEP segments are already extracted in the previous processing. Problems that are fixed only for FPSP V1R3. 1.FPA have been modified to not release work area for estae process. 2.OPC have been modified to output ONLINE POINTER CHECKER STATISTICS report to FPXRPTS DD when used DASYSIN DD. 3.OPC have been modified to output VSO status in ONLINE POINTER CHECKER STATISTICS report.
Temporary fix
Comments
APAR Information
APAR number
PI12789
Reported component name
IMS FP SOLUTION
Reported component ID
5655W1400
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-02-28
Closed date
2014-04-11
Last modified date
2014-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI16975
Modules/Macros
FPXACRBB FPXACRBC FPXACRBD FPXADRVB FPXADRVC FPXADRVD FPXALIF0 FPXASDP0 FPXASUM0 FPXBTOA0 FPXBWTOR FPXCONS0 FPXDLIEB FPXDLIEC FPXDLIED FPXDSDP0 FPXESDP0 FPXGSEGB FPXGSEGC FPXGSEGD FPXMBLK0 FPXMSG00 FPXPSDP0 FPXQOPN0 FPXUSDR0 HAHQ130J HFPAS1D0 HFPA1DC0 HFPA1I10 HFPA1P10 HFPA1SD0 HFPA4SN0 HFPA5H20 HFPA5SR0 HFPLSNC0 HFPMAIN0 HFPOMGT0 HFPQMAI0 HFPREST0 HFPSENSR HFPSPMST HFPSTGEN HFPVICG0 HFPVICI0 HFPWPRC0
Fix information
Fixed component name
IMS FP SOLUTION
Fixed component ID
5655W1400
Applicable component levels
R130 PSY UI16975
UP14/04/13 P F404
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Fast Path Solution Pack"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: