IBM Support

PI09778: FPEV0223E ( 00F30091 ) WHEN RRS NOT AVAILABLE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • FPEV0223E  RS=00F30091 when RRS not active. System waits for
    RRS.  We currently retry for 10 seconds.  This apar will
    increase the wait time to 1 minute.
    .
    A restart of the STC or manual intervention is required.
    Use the following SDSF command to avoid restarting the STC:
    /F xxxxxxxx, F PESERVER,S yyyy
    where xxxxxxxx is the OMEGAMON Collector started task name and
    yyyy the DB2 subsystem ID
    

Local fix

  • Run this command to avoid restarting the STC:
    /F xxxxxxxx, F PESERVER,S yyyy
    where xxxxxxxx is the OMEGAMON Collector started task name and
    STC name and yyyy the DB2 subsystem ID
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - PE Server subtask                          *
    ****************************************************************
    * PROBLEM DESCRIPTION: When the PE Server tries to connect     *
    *                      to a DB2 susbsystem while the DB2       *
    *                      subsystem is starting up, the connect   *
    *                      processing might fail because it does   *
    *                      not complete in time.                   *
    *                      Message FPEV0223E is issued and no      *
    *                      PE Server subtask is started to monitor *
    *                      the DB2 subsystem.                      *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    When the PE Server detects the start up of a DB2 subsystem
    which has to be monitored, the PE Server tries to connect to
    the DB2 subsystem for 10 seconds. If the connection cannot be
    established in time, message FPEV0223E is issued and no
    monitoring PE Server subtask is started.
    
    PROBLEM CONCLUSION:
    The code has been changed. The PE Server performs retry cycles
    until a connection can be established. If the connection cannot
    be established within a 5 minutes interval, the modified
    message FPEV0223E is issued and connect processing continues.
    
    KEYWORDS:
    FPEV0223E RRSAF
    
    CIRCUMVENTION:
    Start the DB2 subsystems first and then start the
    OMEGAMON Collector.
    
    TEMPORARY FIX:
    When message FPEV0223E is issued, the PE Server subtask
    can be started manually using the MODIFY command
    /F stc,F PESERVER,S ssID
    where stc is the name of OMEGAMON Collector started task
    and ssID is the DB2 subsystem ID.
    

Problem conclusion

  • The code has been changed. The PE Server performs retry cycles
    until a connection can be established. If the connection cannot
    be established within a 5 minutes interval, the modified
    message FPEV0223E is issued and connect processing continues.
    
    KEYWORDS:
    FPEV0223E RRSAF
    

Temporary fix

  • When message FPEV0223E is issued, the PE Server subtask
    can be started manually using the MODIFY command
    /F stc,F PESERVER,S ssID
    where stc is the name of OMEGAMON Collector started task
    and ssID is the DB2 subsystem ID.
    

Comments

APAR Information

  • APAR number

    PI09778

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    511

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-01-16

  • Closed date

    2014-03-12

  • Last modified date

    2014-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI15933 UI15934

Modules/Macros

  • DGO@DTA1 DGOVISI  DGOVISIT DGOVMB   DGOVMDSP
    DGOVMSTR DGOVM001 DGOVPIG1 DGOVPP1  DGOVRSFI DGOVRTG0 DGOVRTG1
    DGOVRTG2 DGOZDTA1 DGOZMB   FPEUMSGS FPEVACM  FPEVDB23 FPEVDB27
    FPEVMST2 FPEVRDS1 FPEVRGM  FPEVRTM  FPEVSCM  FPEVTMEM FPEVZRAC
    FPEZPMS
    

Publications Referenced
GH12696500GH12699300   

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R511 PSY UI15933

       UP14/03/14 P F403

  • R520 PSY UI15934

       UP14/03/14 P F403

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
02 April 2014