IBM Support

PI08977: DB SENSOR SUPPORTS DB_AVG_LEN_SYNONYM_CHAIN FOR HDAM AND PHDAM DATABASES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • DB Sensor is enhanced to collect and print a new sensor element
    DB_AVG_LEN_SYNONYM_CHAIN that is the average length of synonym
    chains.
    This APAR is for enabling the enhancement in Integrated DB
    Sensor.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: IBM IMS High Performance Pointer Checker for *
    *                 z/OS Version 3 Release 1 (FMID=HPC2310)      *
    *                 users who run Full Function Database Sensor  *
    *                 (DB Sensor).                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: DB Sensor is enhanced to collect and    *
    *                      print a data element                    *
    *                      DB_AVG_LEN_SYNONYM_CHAIN that is the    *
    *                      average length of synonym chains.       *
    *                      This APAR is for enabling the           *
    *                      enhancement in Integrated DB Sensor.    *
    ****************************************************************
    * RECOMMENDATION: Apply the maintenance for this APAR.         *
    ****************************************************************
    This APAR and PI08979 of IMS DB Reorganization Expert enhance
    DB Sensor to support a data element DB_AVG_LEN_SYNONYM_CHAIN
    for HDAM and PHDAM database in the following_run modes:
    
     - Integrated DB Sensor runs in IMS High Performance Image Copy
       with HDPC=Y.
     - Integrated DB Sensor runs in IMS High Performance Pointer
       Checker.
    
    When SENSOR_HOME is specified as yes in the control statement,
    DB_AVG_LEN_SYNONYM_CHAIN is stored in the Sensor Data
    repository of IMS Tools Knowledge Base, and it is printed
    in the Sensor Data Statistics report of DB Sensor.
    
    To use the new function, apply this APAR and PI08979.
    

Problem conclusion

Temporary fix

Comments

  • The following modules and macros have been modified.
    
    FABPDCT,FABPARCK,FABPDBS0,FABPHINI,FABPHPSD,FABPHSDA,FABPPSDA,
    FABPSDA0,FABPURND
    
    ========================
    = DOCUMENTATION CHANGE =
    ========================
    
     Note: The Part and Chapter numbers are those of the PDF file.
     The documentation is modified as follows:
     ===============================================================
     IBM IMS High Performance Pointer Checker for z/OS, V3R1, User's
     Guide Version 3 Release 1 (SC19240101)
     ===============================================================
     > Part 2. HD Pointer Checker utility
     >> Chapter 4. Using the HD Pointer Checker processor
     >>> Input
     >>>> FABPMAIN PROCCTL data set
     >>>> PROC statement
     >>>>> SENSOR_HOME=
     --------------------------------------------------------------
     Specifies whether to collect the data elements that are related
     to root segment distribution and store them in the Sensor Data
     repository of IMS Tools KB. If SENSOR=YES is not specified,
     this keyword is ignored.
    
     YES
     Collects the following data elements and stores them in the
     Sensor Data repository of IMS Tools KB:
      DB_NUM_ROOT_NOHOME
      DB_PCT_NUM_ROOT_NOHOME
    | DB_AVG_LEN_SYNONYM_CHAIN
    
     SENSOR_HOME=YES is the default value.
     Consideration: When you specify SENSOR_HOME=YES, a randomizer
     is called to collect data for these data elements.
     Therefore, when SENSOR_HOME=YES is specified, the CPU time and
     the elapsed time will increase compared to when SENSOR_HOME=NO
     is specified.
    
     NO
     Does not collect the data elements that are related to root
     segment distribution.
     For information about the data elements that are related to
     root segment distribution, see the explanation of this keyword
     in the IMS Solution Packs: Database Sensor User's Guide.
    

APAR Information

  • APAR number

    PI08977

  • Reported component name

    IMS POINTER CHE

  • Reported component ID

    5655E0900

  • Reported release

    310

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-01-06

  • Closed date

    2014-01-20

  • Last modified date

    2014-02-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI14362

Modules/Macros

  • FABPARCK FABPDBS0 FABPHINI FABPHPSD FABPHSDA FABPPSDA FABPSDA0
    FABPURND
    

Publications Referenced
SC19240102    

Fix information

  • Fixed component name

    IMS POINTER CHE

  • Fixed component ID

    5655E0900

Applicable component levels

  • R310 PSY UI14362

       UP14/01/28 P F401

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Line of Business":{"code":null,"label":null},"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89G","label":"IMS HP Pointer Checker"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.1.0"}]

Document Information

Modified date:
04 October 2020