A fix is available
APAR status
Closed as program error.
Error description
Generating OmPE BATCH Report - . . . GLOBAL(PAGESIZE(56)) RECTRACE( TRACE( LEVEL( LONG ) , INCLUDE ( IFCID(204) ) ) ) EXEC . . . - customer's got such ABEND: . . . 16.14.04 JOB06098 IEA995I SYMPTOM DUMP OUTPUT 047 047 SYSTEM COMPLETION CODE=0C4 REASON CODE=00000011 047 TIME=16.13.56 SEQ=38613 CPU=0000 ASID=01E8 047 PSW AT TIME OF ERROR 078D3000 8003EB9C ILC 4 INTC 11 047 ACTIVE LOAD MODULE ADDRESS=00007000 OFFSET=00037B9C 047 NAME=FPEUFUD2 . . .
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Batch Reporting * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 may be encountered in OMPE * * Batch Reporter while processing * * IFCID 145 or IFCID 204. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: IFCIDs 145 and 204 may cause incorrect long string processing because of their layout difference in different DB2 versions. PROBLEM CONCLUSION: Code changed to fix this problem. KEYWORDS: ABEND0C4 / OMPE BATCH REPORT / FPEUFUD2 / AUDIT FILE
Problem conclusion
Code changed to fix this problem. KEYWORDS: ABEND0C4 / OMPE BATCH REPORT / FPEUFUD2 / AUDIT FILE
Temporary fix
Comments
ž**** PE14/03/13 PTF IN ERROR. SEE APAR PI13644 FOR DESCRIPTION
APAR Information
APAR number
PI07326
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-12-04
Closed date
2014-03-07
Last modified date
2014-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI15811 UI15812 UI15813
Modules/Macros
FPECHE15 FPECHNMP FPEUFTDS FPEUFTS2 FPEUIFCI FPEUIFC2
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R510 PSY UI15811
UP14/03/11 P F403
R511 PSY UI15812
UP14/03/11 P F403
R520 PSY UI15813
UP14/03/11 P F403
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]