IBM Support

PI07186: Conditional rendering not displaying results

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When a conditional variable, based on ReportOutput(), is applied
    to a data container, and a single default output type is
    selected for either a manual or scheduled run/save, the report
    object is not rendered on the report output. For example, if the
    conditional variable is applied to a list to only render if
    ReportOutput() = PDF, the list object will not render.  If
    multiple report output types are selected (e.g. PDF and HTML and
    XLS), then all reports will be generated properly.  However, if
    the same method to render a data container is applied to a
    parent object, for example if the List were nested within a
    Block - and the Rendering Variable were applied to the Block
    instead of the List itself, then all rendering outputs are
    returned as expected.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description.                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to IBM Cognos Business Intelligence 10.2.1 Fix Pack  *
    * 3                                                            *
    ****************************************************************
    

Problem conclusion

  • Code Fix
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI07186

  • Reported component name

    COG REPORT STUD

  • Reported component ID

    5724W12RS

  • Reported release

    A21

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-12-02

  • Closed date

    2014-06-20

  • Last modified date

    2014-06-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    COG REPORT STUD

  • Fixed component ID

    5724W12RS

Applicable component levels

  • RA21 PSN

       UP