IBM Support

PI06713: INCORRECT OR INDETERMINATE STATE FOR WSAS REPORTED BY RAD WHEN WSAS IS STOPPED WITH UNSUPPORTED SYSTEM.EXIT.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using WebSphere Application Server with Rational
    Application Developer, an unsupported call to stop the
    Application Server JVM through System.exit could leave
    Rational Application Developer reporting an incorrect or
    indeterminate state for WebSphere Application Server.
    

Local fix

  • Discontinue use of System.exit to stop WSAS JVM.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: Stopping the Application Server using   *
    *                      an unexpected means results in          *
    *                      incorrect or indeterminate state in     *
    *                      Rational Application Developer          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Rational Application Developer provides tools to monitor the
    state of WebSphere Application Servers, including their
    started or stopped status. That reporting can be misdirected
    when a server is stopped by code calling System.exit() outside
    Application Server control.  This is not generally a supported
    application behavior, but it does occur in practice in
    application scenarios and should be handled reliably.
    

Problem conclusion

  • A new message, code WSVR0023I, is emitted when the server's
    stop process is initiated.  Note that, while this message is
    logged when the server is stopped using a supported stop
    method or a System.exit() call, it will not be logged if the
    process is directly terminated, such as with a "kill" command.
    A separate Rational Application Developer APAR addresses the
    Rational Application Developer behavior associated with this
    issue.
    
    The fix for this APAR is currently targeted for inclusion in
    fix packs 8.0.0.9 and 8.5.5.3.  Please refer to the Recommended
    Updates page for delivery information:
    http://www.ibm.com/support/docview.wss?rs=180&uid=swg27004980
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI06713

  • Reported component name

    WEBSPHERE APP S

  • Reported component ID

    5724J0800

  • Reported release

    800

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-11-21

  • Closed date

    2014-03-14

  • Last modified date

    2014-03-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WEBSPHERE APP S

  • Fixed component ID

    5724J0800

Applicable component levels

  • R800 PSY

       UP

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: