IBM Support

PI05285: CAST_DIVISION_FLOAT RETRIEVES UNEXPECTED RESULTS AGAINST SYBASE IQ 15.4

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • When calculating division for "bigint" type on Sybase IQ. Query
    calculation shows wrong value due to "cast as float". Layout
    calculation retrieves correct value cause it generates the sql
    with "cast as double".??Since Sybase IQ set width of float to  4
    byte,?bigint type should be converted to double (8byte).??Issue
    can be resolved if I force UDA to always generate "cast as
    double" instead of "cast as float".?(Changed codmod_iq.ini) ??Is
    it an intended behavior or a defect ??Can user use this as a
    workaround ?
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to IBM Cognos Business Intelligence 10.2 Refresh     *
    * Pack 2                                                       *
    ****************************************************************
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI05285

  • Reported component name

    COG REPORT STUD

  • Reported component ID

    5724W12RS

  • Reported release

    A11

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-10-31

  • Closed date

    2014-11-22

  • Last modified date

    2014-11-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • RA22 PSN

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHNWW","label":"Report Authoring v11x"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A11","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
27 November 2014