  • This APAR enhances diagnostic capabilities by automatically
    triggering a dump on a HALOAD job, when the Health Monitor
    countdown is activated and the remaining timeout reaches 60
    seconds.
    
    The following address spaces are included in the dump:
    
    The batch address space.
    The ASID(s) associated with the ACCEL_LOAD_TABLES WLM
    application environment used for the load operation.
    The dump title will show the following "DUMP TITLE=HLOUHMON -
    DIAGNOSTIC DUMP"
    
    The dump is generated only on the first occurrence of the Health
    Monitor countdown reaching the 60-second remaining threshold.
    After the dump is triggered, the Loader started task disables
    any further dump requests associated with subsequent Health
    Monitor countdown events.
    
    If the Loader started task is stopped and restarted, the
    internal flag controlling this one-time dump behavior is reset,
    allowing a new dump to be triggered the next time the Health
    Monitor countdown reaches 60 seconds remaining.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: Trigger a diagnostic dump for a HALOAD  *
    *                      loader job when the Health Monitor      *
    *                      countdown reaches 60 seconds remaining  *
    *                      prior to timeout cancellation.          *
    ****************************************************************
    Trigger a diagnostic dump for a HALOAD loader job when the
    Health Monitor countdown reaches 60 seconds remaining prior to
    timeout cancellation.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH72687

  • Reported component name

    IDAA LOADER ZOS

  • Reported component ID

    5639OLA00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2026-08-13

  • Closed date

    2026-09-11

  • Last modified date

    2026-09-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • HLO#A001 HLO#ACIR HLO#ACIW HLO#ACON HLO#ACRD HLO#ACUP HLO#ADIS
    HLO#ADSC HLO#AEXT HLO#AFMT HLO#AFRR HLO#ALLO HLO#AMIN HLO#ASYS
    HLO#AUMX HLO#BIND HLO#CARD HLO#CHKR HLO#CL64 HLO#CLLS HLO#CMTS
    HLO#CNTL HLO#CPNT HLO#CPOL HLO#DSAF HLO#DSPL HLO#DYNL HLO#ENCR
    HLO#ENQS HLO#ENVF HLO#FCPY HLO#ICAI HLO#ICAL HLO#ICCC HLO#ICCI
    HLO#IDCF HLO#IDSA HLO#IERR HLO#IHSA HLO#IKPL HLO#IKPN HLO#ILGP
    HLO#ILRA HLO#ILRS HLO#ILSA HLO#INIT HLO#IPIE HLO#IPPB HLO#IPPC
    HLO#IPPD HLO#IPPH HLO#IPPL HLO#IPPN HLO#IPPS HLO#IRPL HLO#ISNA
    HLO#LGAA HLO#LGAC HLO#LGAF HLO#LGAI HLO#LGAP HLO#LOGR HLO#LRD6
    HLO#MAIN HLO#MDRV HLO#MLOG HLO#MMGR HLO#MREP HLO#MTIO HLO#NREC
    HLO#OS   HLO#PRNG HLO#PRSE HLO#QSAM HLO#RANG HLO#RPRP HLO#RUNT
    HLO#STAT HLO#SUBD HLO#SUBX HLO#SYSC HLO#TUTL HLO#UTLS HLO#VERS
    HLO#VSM  HLO#WRIT HLO#XMLI HLO#XMLJ HLO#XMLS HLO$ACCS HLO$ACES
    HLO$ADMN HLO@CFUP HLOADDTB HLOAPOST HLOBLNKT HLOCAPST HLOCLBK1
    HLOCLBK2 HLOCOMAT HLOEDIT  HLOFTRT  HLOHEXT  HLOIENQS HLOLGRD
    HLOLVALT HLOMMGR  HLONBLKT HLONNUMT HLOPARET HLOPERIT HLOPIPE
    HLOPIPEA HLOPIPEG HLOPOSRV HLOPRPG  HLOPSTPR HLORDELD HLOREBD
    HLOREEXP HLORERD  HLOS99   HLOSINIT HLOUCBAS HLOUDELD HLOUHAL1
    HLOUHLTP HLOUHMON HLOUHTMG HLOUMAIN HLOUNTOK HLOUSE35 HLOUTMGR
    HLOUUMON HLOZSCHD HLOZSRB3
    

Fix information

  • Fixed component name

    IDAA LOADER ZOS

  • Fixed component ID

    5639OLA00

Applicable component levels

  • R310 PSY UO09378

       UP26/09/16 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
16 September 2026