A fix is available
APAR status
Closed as program error.
Error description
The RESOVERRIDES SIT parameter is not returned by the CPSM API in the SYSPARM resource table, and as a result it is not visible in the WUI System Parameters panel.
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All CICSPlex SM Users. * **************************************************************** * PROBLEM DESCRIPTION: CICS region's RESOVERRIDES SIT * * the parameter value is not returned by * * the CPSM API (SYSPARM resource table) * * and is not visible in the CPSM WUI * * System Parameters panel for managed * * CICS TS 6.1 or later regions. * **************************************************************** When using CICSplex SM (CPSM) to manage a CICS TS 6.1 or later region that has the RESOVERRIDES SIT parameter specified, the parameter value is not returned by the CPSM API (SYSPARM resource table) and is not displayed in the CPSM WUI System Parameters panel (EYUSTARTSYSPARM). A CMCI GET request against the SYSPARM resource with PARMTYPE=SIT and PARMSRCE=COMBINED returns RESPONSE=NODATA with a record count of zero when filtering by KEYWORD=RESOVERRIDES. Similarly, navigating to the System Parameters panel in the CPSM WUI for the managed region shows no row for RESOVERRIDES, despite the parameter being actively set in the region SIT or SYSIN and being processed correctly by CICS at startup. No error or warning message is raised at any point. All other SIT parameters are displayed correctly. The problem affects managed CICS regions running CICS TS 6.1, 6.2, and 6.3.
Problem conclusion
The code has been corrected to include the missing RESOVERRIDES SIT parameter.
Temporary fix
Comments
APAR Information
APAR number
PH72498
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
60M
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-07-30
Closed date
2026-08-17
Last modified date
2026-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO08999 UO09000 UO09001
Modules/Macros
CJATNAGA CJBTNAGB CJHTNAGH CJITNAGI CJJTNAGJ EYUTNAGA EYUTNAGB EYUTNAGC
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
R40M PSY UO09001
UP26/08/26 P F608
R50M PSY UO09000
UP26/08/26 P F608
R60M PSY UO08999
UP26/08/19 P F608
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.3","Line of Business":{"code":"LOB70","label":"Z TPS"}}]