IBM Support

PH71572: UNPREDICTABLE AND INTERMITTENT ABEND DURING AN UNLOAD USING BSAMMETHOD

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An unload terminates in abend if all the following conditions
    are fulfilled:
    - zIIP usage is active
    - at least one of the following conditions is true:
       - the data are unloaded to a sequential dataset and the BSAM
         method is used for OUTPUT datasets (as reported by the
         INZ666I message)
       - (in HPU 6.1 only) a dataset is alloacted for the INDEXSCAN
         feature (as reported by the INZX111 message) is used to
         process the unload and the BSAM method is used for the
         INDEXSCAN datasets (as reported by the INZ666I message)
    - a very precise timing condition between Db2 HPU internal
      threads is fulfilled
    
    The required timing condition makes this issue very rare and
    intermittent.
    
    
    Local fix: A new run of the failing unload can terminate
    successfully but the issue may be completely avoided by request
    the QSAM method for the concerned type of dataset (OUTPUT or
    INDEXSCAN). For example, specify
    IO_SEQ_METHOD OUTPUT(QSAM),INDEXSCAN(QSAM) in the GLOBAL option
    block.
    

Local fix

  • A new run of the failing unload can terminate successfully but
    the issue may be completely avoided by request the QSAM method
    for the concerned type of dataset (OUTPUT or INDEXSCAN). For
    example, specify IO_SEQ_METHOD OUTPUT(QSAM),INDEXSCAN(QSAM) in
    the GLOBAL option block.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Db2 High Performance Unload for     *
    *                 z/OS                                         *
    ****************************************************************
    * PROBLEM DESCRIPTION: An unload terminates in abend if all    *
    *                      the following conditions are fulfilled: *
    *                      - zIIP usage is active                  *
    *                      - at least one of the following         *
    *                        conditions is true:                   *
    *                         - the data are unloaded to a         *
    *                           sequential dataset and the BSAM    *
    *                           method is used for OUTPUT datasets *
    *                           (as reported by the INZ666I        *
    *                           message)                           *
    *                         - (in HPU 6.1 only) a dataset is     *
    *                           alloacted for the INDEXSCAN        *
    *                           feature (as reported by the        *
    *                           INZX111 message) is used to        *
    *                           process the unload and the BSAM    *
    *                           method is used for the INDEXSCAN   *
    *                           datasets (as reported by the       *
    *                           INZ666I message)                   *
    *                      - a very precise timing condition       *
    *                        between Db2 HPU internal threads is   *
    *                        fulfilled                             *
    *                                                              *
    *                      The required timing condition makes     *
    *                      this issue very rare and intermittent.  *
    *                                                              *
    *                                                              *
    *                      Local fix: A new run of the failing     *
    *                      unload can terminate successfully but   *
    *                      the issue may be completely avoided by  *
    *                      request the QSAM method for the         *
    *                      concerned type of dataset (OUTPUT or    *
    *                      INDEXSCAN). For example, specify        *
    *                      IO_SEQ_METHOD OUTPUT(QSAM),             *
    *                      INDEXSCAN(QSAM) in the GLOBAL option    *
    *                      block.                                  *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF                                *
    ****************************************************************
    Unpredictable and intermittent ABEND during an unload using BSAM
    method
    

Problem conclusion

  • Code has been changed to fix this problem
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH71572

  • Reported component name

    DB2 HI PERF UNL

  • Reported component ID

    5697F4400

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2026-06-02

  • Closed date

    2026-06-03

  • Last modified date

    2026-07-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH71573

Modules/Macros

  • INZUTILK
    

Fix information

  • Fixed component name

    DB2 HI PERF UNL

  • Fixed component ID

    5697F4400

Applicable component levels

  • R610 PSY UO08108

       UP26/07/02 P F606

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
02 July 2026