A fix is available
APAR status
Closed as program error.
Error description
An issue may occur where an incorrect LOADCARD WHEN statement is generated for a reporting table when either the table owner or the table name has a length of 14 bytes. In this situation, the value is incorrectly encoded in hexadecimal format, which can lead to an _INVALID CHARACTER OPERAND_ message. This APAR corrects the generation of the WHEN statement to ensure proper handling of such cases.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Db2 Log Analysis Tool for z/OS * **************************************************************** * PROBLEM DESCRIPTION: An issue may occur where an incorrect * * LOADCARD WHEN statement is generated * * for a reporting table when either the * * table owner or the table name has a * * length of 14 bytes. * * In this situation, the value is * * incorrectly encoded in hexadecimal * * format, which can lead to an INVALID * * CHARACTER OPERAND message. * * This APAR corrects the generation of * * the WHEN statement to ensure proper * * handling of such cases. * **************************************************************** * RECOMMENDATION: Apply the PTF * **************************************************************** Possible incorrect LOADCARD generation with INVALID CHARACTER OPERAND message
Problem conclusion
Apply the PTF
Temporary fix
Comments
APAR Information
APAR number
PH71451
Reported component name
DB2 LOG ANALYSI
Reported component ID
5655E6601
Reported release
360
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-05-22
Closed date
2026-06-11
Last modified date
2026-06-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO08185
Modules/Macros
ALA#LCLF ALACLDEL ALAGLOAD ALALAUD
Fix information
Fixed component name
DB2 LOG ANALYSI
Fixed component ID
5655E6601
Applicable component levels
R360 PSY UO08185
UP26/06/16 I 1000
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.