A fix is available
APAR status
Closed as program error.
Error description
When "LENGTH OF" special register is used with fixed character position UTF-8 data items with not other reference to them, compiler abends with error code IGYPG5125-U and IGYPG5201-U
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.4 compiling a * * COBOL program that contains usage of the * * LENGTH OF special register with a fixed * * character length UTF-8 data item. * **************************************************************** * PROBLEM DESCRIPTION: Compiler aborts with messages: * * * * 1. IGYPG5125-U The compilation was * * terminated due to a compiler error in * * phase id: "IGYCPGEN". * * * * 2. IGYPG5201-U Internal compiler error * * code "TALIA-E7" occurred. * **************************************************************** * RECOMMENDATION: Apply the IBM-provided PTF. * **************************************************************** The compiler failed to recognize the reference to a fixed character length UTF-8 data item when used with LENGTH OF special register which cause the compiler to abort with internal compiler error.
Problem conclusion
The compiler was updated to ensure that LENGTH OF special register can be used correctly with fixed character length UTF-8 data items.
Temporary fix
Comments
APAR Information
APAR number
PH71341
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
650
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-05-14
Closed date
2026-05-14
Last modified date
2026-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2 IGYCOB2E IGYCOPI IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYMSGXT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R650 PSY UO07832
UP26/05/22 P F605
R651 PSY UO07833
UP26/05/22 P F605
R652 PSY UO07834
UP26/05/22 P F605
R65H PSY UO07835
UP26/05/22 P F605
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.5","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: