IBM Support

PH71218: LCP PROFILE DOES NOT HONOR 10-MINUTE SGC INTERVAL DUE TO MINIMUM INTERVAL CONFLICT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Was identified a potential issue when configuring an LCP profile
    with an SGC interval set to MINUTE(10). The system does not
    consistently honor the configured 10-minute interval due to a
    conflict with the minimum allowed time between captures, which
    is also defined as MINUTE(10).
    
    As a result, some SGC executions are silently skipped because
    the required minimum time between captures has not yet elapsed.
    This behavior prevents SGCs from being taken at the expected
    10-minute frequency, leading to gaps in data collection.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: GDPS Metro and GDPS Global - GM users        *
    *                 exploiting LCP Manager                       *
    ****************************************************************
    * PROBLEM DESCRIPTION: LCP scheduled Safeguarded Captures may  *
    *                      be skipped when the Minimum Interval    *
    *                      and Capture Interval management profile *
    *                      fields are set to the same value.       *
    ****************************************************************
    When the Minimum Interval and Capture Interval Safeguarded Copy
    management profile fields are set to the same value, slight
    timing changes may cause captures to be skipped due to the
    Minimum Interval not having elapsed.
    
    The Minimum Interval should be set to a lower value than the
    Capture Interval, but when the Capture Interval is set to
    MINUTE(10), it is impossible to set the Minimum Interval lower
    since both values have MINUTE(10) as their lowest possible
    value.
    

Problem conclusion

  • This PTF corrects the reported problems by allowing the Minimum
    Interval of Safeguarded Copy and FlashCopy management profiles
    to be set as low as MINUTE(5).
    
    DOCUMENTATION CHANGES
    The GDPS Logical Corruption Protection Manager Installation and
    Customization Guide (ZG24-6763) and Stand-alone LCP Manager
    Installation and Customization Guide (ZG24-6765) are updated
    with the new Minimum Interval value range for FlashCopy and
    Safeguarded Copy management profiles.
    
     Minimum Interval
     The minimum amount of time that must elapse before a new
     capture is permitted. The value specified must be equal or
     less than the retention period. The minimum capture interval
     can be specified as:
      MINUTE(n) Where n is a value between 5 and 9999
      HOUR(n) Where n is a value between 1 and 999
      DAY(n) Where n is a value between 1 and 999
    
    KEYWORDS: GDPSLCPMGR/K
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH71218

  • Reported component name

    GDPS

  • Reported component ID

    694235B00

  • Reported release

    480

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2026-05-07

  • Closed date

    2026-06-05

  • Last modified date

    2026-06-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO08157 UO08158 UO08159 UO08160 UO08161 UO08162

Modules/Macros

  • GEOGUIUS VPCEMP00 VPCPHL07
    

Fix information

  • Fixed component name

    GDPS

  • Fixed component ID

    694235B00

Applicable component levels

  • R470 PSY UO08161

       UP26/06/09 I 1000

  • R47B PSY UO08162

       UP26/06/09 I 1000

  • R480 PSY UO08159

       UP26/06/09 I 1000

  • R48B PSY UO08160

       UP26/06/09 I 1000

  • R490 PSY UO08157

       UP26/06/09 I 1000

  • R49B PSY UO08158

       UP26/06/09 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SSET85","label":"GDPS (Geographically Dispersed Parallel Sysplex)"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"480","Line of Business":{"code":"LOB66","label":"Technology Lifecycle Services"}}]

Document Information

Modified date: