Error description

  • IMS PA FPIRUC report displays an incorrect System Totals when
    the value is greater than 9999999. For example:
    
    Fast Path Resource Usage and Contention Total
         IMS1  System Totals: 5038280
         IMS3  System Totals: 5739450
         Total  System Totals: 77730
    (5038280 + 5739450 = 10777730, but printed as 77730)
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of IMS Performance Analyzer V4.5       *
    ****************************************************************
    * PROBLEM DESCRIPTION: IMS PA Fixed Format report FPIRUC       *
    *                      Fast Path Resource Usage and Contention *
    *                      has incorrect System Totals due to      *
    *                      value overflow.                         *
    ****************************************************************
    IMS PA Fixed Format report FPIRUC Fast Path Resource Usage and
    Contention has incorrect System Totals due to value overflow.
    If the value exceeds 9999999 a blank may display for the
    high-order digit.
    

Problem conclusion

  • There are seven digits available in the System Totals column.
    The code has been changed to display 9999999 for values
    exceeding this number. A blank will not be displayed for
    the high order digit.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH71062

  • Reported component name

    IMS PERF ANALYZ

  • Reported component ID

    5655E1500

  • Reported release

    450

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2026-04-27

  • Closed date

    2026-05-15

  • Last modified date

    2026-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO07844

Modules/Macros

  • IPISAPAR IPISFPIR
    

Fix information

  • Fixed component name

    IMS PERF ANALYZ

  • Fixed component ID

    5655E1500

Applicable component levels

  • R450 PSY UO07844

       UP26/05/20 P F605

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"450"}]

Document Information

Modified date:
01 June 2026