A fix is available
APAR status
Closed as program error.
Error description
Runaway triggered an AKEC abend when the IPIC connection became stuck in a loop. DFHIS0001 AN ABEND (CODE ---/AKEC) HAS OCCURRED AT OFFSET X'FFFF' IN MODULE DFHISIS. DFHME0116 (MODULE:DFHMEME) CICS SYMPTOM STRING FOR MESSAGE DFHIS0001 IS PIDS/5655Y0400 LVLS/730 MS/DFHIS0001 RIDS/DFHISIS PTFS/UI97946 AB/UAKEC ADRS/0000FFFF DFHIS0002 A SEVERE ERROR (CODE X'0686') HAS OCCURRED IN MODULE DFHISXM. DFHME0116 (MODULE:DFHMEME) CICS SYMPTOM STRING FOR MESSAGE DFHIS002 IS PIDS/5655Y0400 LVLS/730 MS/DFHIS0002 RIDS/DFHISXM PTFS/UI97946 PRCS/00000686 DFHIS0001 AN ABEND (CODE 0C4/AKEA) HAS OCCURRED AT OFFSET X'10B8' IN MODULE DFHISZA. DFHME0116 (MODULE:DFHMEME) CICS SYMPTOM STRING FOR MESSAGE DFHIS0001 IS PIDS/5655Y0400 LVLS/730 MS/DFHIS0001 RIDS/DFHISZA PTFS/UI97946 AB/S00C4 AB/UAKEA ADRS/000010B8
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Users * **************************************************************** * PROBLEM DESCRIPTION: AKEC and AKEA abends occur when an IPIC * * connection is stuck in a loop and * * runaway detection triggered. * **************************************************************** When processing incoming IPIC messages, memory corruption caused the field data pointer to incorrectly point to DFHEIUS storage instead of a valid IPIC message buffer. This resulted in a zero-length field value, creating an infinite loop that triggered runaway detection and triggered an AKEC abend.
Problem conclusion
We have added validation to detect zero-length fields before entering the loop. When detected, CICS issues DFHIS0002 and abends only the affected task.
Temporary fix
Comments
APAR Information
APAR number
PH71031
Reported component name
CICS TS Z/OS V6
Reported component ID
5655YA100
Reported release
400
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-04-23
Closed date
2026-08-10
Last modified date
2026-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO08936 UO08937 UO08938
Modules/Macros
DFHISIS
Fix information
Fixed component name
CICS TS Z/OS V6
Fixed component ID
5655YA100
Applicable component levels
R400 PSY UO08938
UP26/08/14 P F608
R500 PSY UO08937
UP26/08/13 P F608
R600 PSY UO08936
UP26/08/13 P F608
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.