Error description

  • CICS may run tasks in the wrong priority.  This may occur
    irrespective of priority ageing ( PRTYAGE ) being active.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Task priority might be set incorrectly. *
    ****************************************************************
    In SET_PRIORITY the old priority is saved but the new priority
    is not updated. The most recent priority value is therefore not
    available to later processing.
    

Problem conclusion

  • CICS has been changed to set task priority correctly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH70950

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    600

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2026-04-17

  • Closed date

    2026-09-24

  • Last modified date

    2026-09-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO09647

Modules/Macros

  • DFHDSAT
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R600 PSY UO09647

       UP26/09/26 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.3","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date:
26 September 2026