IBM Support

PH70902: JOB BUILD CAN GENERATE WRONG OBJECTS DUE TO A PROFILE CONVERSION ERROR WHEN THE 1ST EXCEPTION VALUE SPECIFIED IS AN INTEGER

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The job build can result in the wrong objects being selected due
    to an exception profile conversion error that can occur when the
    first exception rule specified contains an INTEGER value.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Users                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: This PTF fixes the following issue:     *
    *                                                              *
    *                      The job build can result in the wrong   *
    *                      objects being selected due to an        *
    *                      exception profile conversion error that *
    *                      can occur when the first exception rule *
    *                      specified contains an INTEGER value.    *
    ****************************************************************
    * RECOMMENDATION: APPLY the PTF                                *
    ****************************************************************
    .
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PH70902

  • Reported component name

    DB2 AUTOMATION

  • Reported component ID

    5697G6300

  • Reported release

    430

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2026-04-14

  • Closed date

    2026-05-06

  • Last modified date

    2026-06-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO07720

Modules/Macros

  • HAA#EPRI
    

Fix information

  • Fixed component name

    DB2 AUTOMATION

  • Fixed component ID

    5697G6300

Applicable component levels

  • R430 PSY UO07720

       UP26/05/09 P F605

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJXP","label":"DB2 Tools for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.3.0","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: