A fix is available
APAR status
Closed as program error.
Error description
ABENDS0CF in IPIACOMM at x'1718' when running an IMS PA Monitor Report. S0CF
Local fix
Remove the IMSPAMON COMMS command keywords of SUMMARY and IWAIT, as it runs fine with just the LINEFUNC keyword.
Problem summary
**************************************************************** * USERS AFFECTED: Users of IMS Performance Analyzer V4.5 * **************************************************************** * PROBLEM DESCRIPTION: Abend S0CF in IPIACOMM+x'01718' * **************************************************************** Abend S0CF 0-divide exception due to value of 0 for Elapsed time.
Problem conclusion
Correct code to avoid S0CF Abend by checking Elapsed time for 0 before divide.
Temporary fix
Comments
APAR Information
APAR number
PH70851
Reported component name
IMS PERF ANALYZ
Reported component ID
5655E1500
Reported release
450
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-04-09
Closed date
2026-04-20
Last modified date
2026-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO07540
Modules/Macros
IPIACOMM IPISAPAR
Fix information
Fixed component name
IMS PERF ANALYZ
Fixed component ID
5655E1500
Applicable component levels
R450 PSY UO07540
UP26/04/23 P F604
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX8A2","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"450"}]
Document Information
Modified date:
02 May 2026