Error description
This problem occurs during extended batch processing ( PGM=HPCAMAIN ) when a system ABEND occurs in the HPCABAT0 module. The HPCAMAIN program calls the HPCABAT0 as a subtask. When a system ABEND occurs in HPCABAT0, HPCAMAIN receives the ABEND code. However, it sets the STEP return code to RC=0000 because it does not correctly handle the received ABEND code.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of the IMS High Performance * * Change Accumulation Utility of IMS Recovery * * Solution Pack for z/OS Version 2 Release 1 * * ( FMID=HAHM210 ). * **************************************************************** * PROBLEM DESCRIPTION: Even if a system ABEND occurs in * * HPCABAT0, the extended batch (HPCAMAIN * * program) still terminates with RC=00. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** Even if a system ABEND occurs in HPCABAT0, the extended batch (HPCAMAIN program) still terminates with RC=00. The HPCAMAIN program attaches HPCABAT0 as a subtask. When a system ABEND occurs in HPCABAT0, the HPCAMAIN program receives the system ABEND code. However, the error handling logic in HPCAMAIN is incorrect, causing it to terminate by setting the JOB step return code to zero.
Problem conclusion
In the event of a system ABEND, the error handling logic for HPCABAT0 in extended batch mode has been modified to set the final RC to 20.
Temporary fix
Comments
APAR Information
APAR number
PH70436
Reported component name
IMS RCVR SOLUTN
Reported component ID
5655V8600
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-03-09
Closed date
2026-03-25
Last modified date
2026-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO07259
Modules/Macros
HPCAMAIN
Fix information
Fixed component name
IMS RCVR SOLUTN
Fixed component ID
5655V8600
Applicable component levels
R210 PSY UO07259