A fix is available
APAR status
Closed as program error.
Error description
This Roll Up PTF fixes the following Internal Issues with Exceptions dealing with DSNACCOX: 1) DSNACCOX - Runstats utility - Exceptions are not triggering objects as expected 2) DSNACCOX - DAJ498E - The specified value, coupled with the comparison type being used, will always be computed to unconditionally false. This error message will be displayed when the user enters a value in the exception condition field that is the maximum value for the column type that underlies the field. This occurs, for example, when the comparison is a "GT" (greater than) operator, the underlying number type is a SMALLINT, and the entered value is 32767. Although 32767 could be true with the GE operator, with GT - the condition could never compute to true.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Users * **************************************************************** * PROBLEM DESCRIPTION: This Roll Up PTF fixes the following * * Internal Issues with Exceptions dealing * * with DSNACCOX: * * * * 1) DSNACCOX - RUNSTATS utility - * * Exceptions are not triggering objects * * as expected * * 2) DSNACCOX - New Error Message * * DAJ498E: * * * * DAJ498E - The specified value, * * coupled with the comparison type * * being used, will always be computed * * to unconditionally false. * * * * This error message will be displayed * * when the user enters a value in the * * exception condition field that is the * * maximum value for the column type that * * underlies the field. This occurs, for * * example, when the comparison is a "GT" * * (greater than) operator, the underlying * * number type is a SMALLINT, and the * * entered value is 32767. Although 32767 * * could be true with the GE operator, * * with GT - the condition could never * * compute to true. * **************************************************************** * RECOMMENDATION: APPLY the PTF * **************************************************************** .
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH70407
Reported component name
AUTOMATION EXPE
Reported component ID
5698DAE00
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-03-05
Closed date
2026-04-21
Last modified date
2026-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO07551
Modules/Macros
DAJ#EPRI DAJ#ERTI DAJ$EPRU DAJ$ETRG DAJ$EXCP DAJ49 DAJ498E
Fix information
Fixed component name
AUTOMATION EXPE
Fixed component ID
5698DAE00
Applicable component levels
R110 PSY UO07551
UP26/04/23 P F604
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSSXEC9","label":"IBM Db2 Automation Expert for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date: