A fix is available
APAR status
Closed as program error.
Error description
This problem occurs when the CA2PITCA DSN parameter is enabled in the PITCA processing. HPCA internally calls the IMS DBRC utility, and reads its results from the data set of SYSPRINT DD. If the IMS message DSP0712I is found in the result of the utility, HPCA immediately issues the DBRC API macro using the same SYSPRINT DD. AS a result, a SYSPRINT DD access contention occurs, causing ABEND S001-3 ( ABENDS001 RSN3 ).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of the IMS High Performance * * Change Accumulation Utility of IMS Recovery * * Solution Pack for z/OS Version 2 Release 1 * * ( FMID=HAHM210 ). * **************************************************************** * PROBLEM DESCRIPTION: When PITCA processing is run with the * * CA2PITCA DSN parameter and a CA group * * that has no update log records to apply * * is found, IMS HP Change Accumulation * * terminates with ABEND S001-00000003 * * ( ABENDS001 RSN3 ). In this case, * * message IEC020I 001-3 * * ( MSGIEC020I RC3 ) is issued for * * the SYSPRINT DD. * **************************************************************** * RECOMMENDATION: INSTALL CORRECTIVE SERVICE FOR APAR/PTF * **************************************************************** When PITCA processing is run with the CA2PITCA DSN parameter and a CA group that has no update log records to apply is found, IMS HP Change Accumulation terminates with ABEND S001-00000003 ( ABENDS001 RSN3 ). In this case, message IEC020I 001-3 (MSGIEC020I RC3) is issued for the SYSPRINT DD. IMS HP Change Accumulation reads the SYSPRINT DD report to check the result of the DBRC Utility that it issues internally. When IMS HP Change Accumulation finds the message DSP0712I ( MSGDSP0712I ) in the report, it calls a DBRC API to issue the NOTIFY.CA command. At this time, IMS HP Change Accumulation also uses the same SYSPRINT DD as the output destination for DBRC API messages, causing a conflict. Consequently, the IMS HP Change Accumulation process triggers an ABEND S001 RSN3 during the subsequent SYSPRINT DD read operation.
Problem conclusion
To avoid output conflicts between the DBRC utility and DBRC API, IMS HP Change Accumulation has been modified to output DBRC API results to the new DD name of HPCADAPI. If it is not specified in JCL, IMS HP Change Accumulation will allocate it dynamically.
Temporary fix
Comments
APAR Information
APAR number
PH70176
Reported component name
IMS RCVR SOLUTN
Reported component ID
5655V8600
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-02-17
Closed date
2026-02-27
Last modified date
2026-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO06987
Modules/Macros
HPCALST0
Fix information
Fixed component name
IMS RCVR SOLUTN
Fixed component ID
5655V8600
Applicable component levels
R210 PSY UO06987
UP26/03/03 P F603
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.