A fix is available
APAR status
Closed as new function.
Error description
SMF 82 Subtype 31 records are not tolerated or exploited.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All IBM Z Performance and Capacity Analytics * * 3.1.0 users. * **************************************************************** * PROBLEM DESCRIPTION: 1. SMF 82 subtype 31 records are not * * tolerated. * * 2. ICSF tables populating SMF 82 * * subtype 31 record data are not * * defined. * **************************************************************** * RECOMMENDATION: Apply the provided PTF(s). * **************************************************************** 1. There is no SMF 82 subtype 31 record definition. 2. There are no ICSF tables populating SMF 82 subtype 31 record data.
Problem conclusion
Temporary fix
Comments
1. A new SMF 82 subtype 31 record definition is defined. 2. The tables MVSPM_ICSF_T, MVSPM_ICSF_ENG_T, MVSPM_ICSF_SRV_T, MVSPM_ICSF_UDX_T, and MVSPM_ICSF_SRV_T populating SMF 82 subtype 31 record data are defined.
APAR Information
APAR number
PH69825
Reported component name
TDS FOR Z/OS
Reported component ID
569510100
Reported release
C01
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
YesSpecatt / New Function / Xsystem
Submitted date
2026-01-26
Closed date
2026-03-24
Last modified date
2026-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO07254 UO07255
Modules/Macros
DRLDOD80 DRLIMP DRLISMF DRLRS082 DRLSMPMB DRLTICSF DRLUICSF
Fix information
Fixed component name
TDS FOR Z/OS
Fixed component ID
569510100
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS2DUM","label":"IBM Z Decision Support"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C01","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
02 May 2026