A fix is available
APAR status
Closed as program error.
Error description
When the IMS HP Image Copy is run with DEDBPC=(Y), the hash check process may terminate abnormally with S0C6. This abnormal termination can occur when the hash check process is being processed simultaneously by multiple tasks.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All users of HPFPU Hash Check support for * * IMS HP Image Copy in Fast Path Solution Pack * * Version 2 Release 1 (FMID: HAHQ210). * **************************************************************** * PROBLEM DESCRIPTION: When the IMS HP Image Copy is run with * * DEDBPC=(Y), the hash check process may * * terminate abnormally with S0C6 or * * U4049. * **************************************************************** * RECOMMENDATION: Apply the maintenance for this APAR * **************************************************************** When the hash check process writes to the MSGOUT DD simultaneously in multiple tasks, an incorrect work area address is returned from the PUT process due to an OS restriction. This causes the hash check process to fail to return to the correct caller after PUT, resulting in an abnormal termination of S0C6 or U4049.
Problem conclusion
The hash check process has been modified to serialize PUT operation for MSGOUT, ensuring it can correctly return to the caller. As a result of this modification, the title line of MSGOUT will be output only once at the beginning.
Temporary fix
Comments
APAR Information
APAR number
PH69546
Reported component name
IMS FP SOLUTION
Reported component ID
5655W1400
Reported release
210
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-01-05
Closed date
2026-01-16
Last modified date
2026-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO06503
Modules/Macros
FABAHEXT FABAQRPT
Fix information
Fixed component name
IMS FP SOLUTION
Fixed component ID
5655W1400
Applicable component levels
R210 PSY UO06503
UP26/01/17 P F601
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCV35A","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"210"}]
Document Information
Modified date:
01 February 2026