Error description
Compiler abort when comparing a UTF-8 literal with a non-UTF-8 data item. Incorrect results when moving UTF-8 ALL literal to non-UTF-8 receiver.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 6.4 compiling and * * running a COBOL program that contains either * * of the following: 1. a comparison of a UTF-8 * * literal with a non-UTF-8 data item; or 2. a * * move of a UTF-8 ALL literal into a non-UTF-8 * * data item. * **************************************************************** * PROBLEM DESCRIPTION: 1. For comparisons, compiler abort * * with message: * * * * IGYPG5306-U An internal compiler error * * occurred. Condition (F) failed at * * IGYPCXU-32770-IGYZCNUL: expected * * alphanum * * * * 2. For ALL literal moves, incorrect * * runtime results. The ALL literal * * value is not repeated in the * * receiver. * **************************************************************** * RECOMMENDATION: Apply the IBM-provided PTF. * **************************************************************** Incorrect code was being generated for comparisons of UTF-8 literals with non-UTF-8 data items. For the move of a UTF-8 ALL literal to a non-UTF-8 data item, the ALL status of the literal was inadvertently being lost during the conversion of the literal to the target codepage during the move.
Problem conclusion
The compiler was updated to ensure UTF-8 literals can be correctly used with non-UTF-8 data items in both MOVE and compare operations.
Temporary fix
Comments
APAR Information
APAR number
PH68878
Reported component name
ENT COBOL FOR Z
Reported component ID
5655EC600
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-11-07
Closed date
2025-12-12
Last modified date
2026-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGY8CICS IGY8RWRD IGY8RWTU IGYCASMB IGYCCBE IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJGEN IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOPI IGYCOPT IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF IGYDRV IGYEQCWI IGYMSGE IGYMSGK IGYMSGT IGYQCBE IGYQSPLT IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655EC600
Applicable component levels
R640 PSY UO06213
UP25/12/18 P F512
R641 PSY UO06214
UP25/12/18 P F512
R642 PSY UO06215
UP25/12/18 P F512
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB70","label":"Z TPS"}}]
Document Information
Modified date:
02 January 2026