Error description

  • NEW FUNCTION: Option SMARTBIN(NAMES) adds information about the
    names of user symbols to the binary metadata
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL 6.4 compiling      *
    *                 COBOL programs that will be analyzed         *
    *                 by IBM watsonx Code Assistant for Z          *
    *                 Code Optimization Advice and require         *
    *                 more accurate matching of problem            *
    *                 recommendations to user symbols.             *
    ****************************************************************
    * PROBLEM DESCRIPTION: New function:  A new option,            *
    *                      SMARTBIN(NAMES|NONAMES), is             *
    *                      provided to let users indicate that     *
    *                      information about the names of          *
    *                      user symbols should be added to         *
    *                      the additional binary metadata.         *
    *                                                              *
    *                      Since IBM watsonx Code Assistant for Z  *
    *                      Code Optimization Advice uses the       *
    *                      names of user symbols in its report of  *
    *                      problems in the source code, having     *
    *                      this information included in the binary *
    *                      metadata in the COBOL modules will      *
    *                      provide for more accurate matching      *
    *                      of problem recommendations to           *
    *                      user symbols.                           *
    *                                                              *
    *                      The default is SMARTBIN(NONAMES)        *
    *                      which preserves existing behaviour.     *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    Information about the names of user symbols is not
    currently available in the binary metadata, and is not
    needed by IBM Automatic Binary Optimizer for z/OS when
    using that product to automatically optimize COBOL
    modules.  Users of IBM watsonx Code Assistant for Z Code
    Optimization Advice are recommended to use this option
    to improve analysis results.
    

Problem conclusion

Temporary fix

Comments

  • The compiler was updated to provide the SMARTBIN(NAMES|NONAMES)
    option. This option allows users to control the inclusion/
    omission of
    information about the names of user symbols in the binary
    metadata.
    
    For a more detailed description of changes, please refer to the
    following
    section in the Enterprise COBOL for z/OS 6.4 IBM Documentation
    online:
    
    1. Programming Guide -> Compiling and debugging your program ->
        COBOL compiler and runtime options ->
        Compiler Options -> SMARTBIN
    
    2. Customization Guide -> Enterprise COBOL compiler options ->
         SMARTBIN
    

APAR Information

  • APAR number

    PH68581

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    640

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-10-17

  • Closed date

    2025-10-27

  • Last modified date

    2025-11-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8CICS IGY8RWRD IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS
    IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2
    IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN
    IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4
    IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R IGYCJGEN IGYCLIBR IGYCLSTR
    IGYCLVL0 IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOB2E
    IGYCOPI  IGYCOPT  IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR IGYCRDSC
    IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1 IGYCUE$2
    IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R IGYCXREF
    IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE  IGYQSPLT
    IGYZQEN6 IGYZQENU IGYZQJP6 IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R640 PSY UO05555

       UP25/11/06 P F511

  • R641 PSY UO05556

       UP25/11/06 P F511

  • R642 PSY UO05557

       UP25/11/06 P F511

  • R64H PSY UO05558

       UP25/11/06 P F511

Fix is available