IBM Support

PH68380: 0 LENGTH GETMAIN IN EYU9XDJG AT OFFSET X'20A8'

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • You see Invalid_length_on_getmain_for_CICS31_class_storage
    exception trace entries in your WUI region's internal trace
    table.  The RET address on the EIP ENTRY for the failing GETMAIN
    indicates the call came from EYU9XDJG + x'20A8'.  You may also
    notice that this happens after a GRAPHQL query which returns no
    records from your CICSplex, such as a query for a resource type
    that you do not have defined.
    
    The same result could occur if selection criteria caused the
    rejection of all existing resources.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICSPlex SM users                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: When using GraphQL to inquire on        *
    *                      resources where an empty result set     *
    *                      would be returned CICS trace records    *
    *                      are written and no records are returned *
    *                      which is the correct result.            *
    ****************************************************************
    * RECOMMENDATION: To activate the fix the CICSPlex SM WUI      *
    *                 server address spaces and SMSS address       *
    *                 spaces configured with CPSMCONN=SMSSJ should *
    *                 be restarted.                                *
    ****************************************************************
    When using GraphQL to inquire on a resource for which an empty
    result set will be returned the WUI performs an EXEC CICS
    GETMAIN to hold the records to be returned. If no records will
    be returned the EXEC CICS GETMAIN has length=0 and fails,
    generating several trace entries.
    
    The query fails and no records are returned, which in this case
    is the correct answer. Nothing untoward is seen by the end user.
    

Problem conclusion

  • The EYU9XDJG module has been updated to correctly handle the
    case where no records are found.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH68380

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    YesSpecatt / CST / Xsystem

  • Submitted date

    2025-10-02

  • Closed date

    2025-11-20

  • Last modified date

    2025-12-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO05879 UO05880

Modules/Macros

  • EYU9XDJG
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R50M PSY UO05880

       UP25/11/26 P F511

  • R60M PSY UO05879

       UP25/11/26 P F511

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.2","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date:
11 December 2025