IBM Support

PH68292: INCORRECTLY INITIALIZED ESTAEX PARAMETER LIST RESULTS IN THE POSSIBILITY FOR ATTLS WORKER TASKS TO RUN WITHOUT ESTAE RECOVERY.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • For an ATTLS worker task that does not have ESTAE recovery,
    if an ABEND occurs under this work unit (i.e. during TLS
    Handshake, etc.), then the ATTLS Group will fail (as per
    EZD2042I message output to SYSLOG).
    
    Typically, an ABEND in load module GSKS64 will be the trigger
    condition for this problem - symptom dump output documenting
    the ABEND will be present in the MVS SYSLOG.
    
    ATTLS group failure will result in connectivity failures for all
    subsequent traffic associated with the group. Each connectivity
    failure will have a corresponding 'EZD1286I TTLS Error' message
    with 'RC: 5018 Policy Mapping' in the MVS SYSLOG.
    
    Additionally, no dump will be captured for further diagnosis
    because ESTAE recovery was not established.
    

Local fix

  • N/A
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IBM z/OS Communications Server  *
    *                 2.5, 3.1, and 3.2 for IP: ATTLS              *
    ****************************************************************
    * PROBLEM DESCRIPTION: An ABEND occurring under a single ATTLS *
    *                      worker task can result in connectivity  *
    *                      loss for all subsequent connections     *
    *                      associated with that group.             *
    *                                                              *
    *                      Furthermore, no SVC dump will be        *
    *                      captured for the problem because there  *
    *                      is no ESTAE recovery established for    *
    *                      the task.                               *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    ****************************************************************
    For an ATTLS worker task that does not have ESTAE recovery,
    if an ABEND occurs under this work unit (i.e. during TLS
    Handshake, etc.), then the ATTLS Group will fail, resulting in
    connectivity loss for all subsequent connections associated to
    the group. Additionally, there is no SVC dump captured to
    further diagnose the problem.
    
    The root cause for this issue is a lack of ESTAE recovery
    protecting the ATTLS worker task. This is caused by incorrect
    initialization of the input parameter list to the ESTAEX
    service at worker task creation time.
    

Problem conclusion

  • ATTLS has been fixed to correctly establish ESTAE recovery.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH68292

  • Reported component name

    TCP/IP MVS

  • Reported component ID

    5655HAL00

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    YesHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-09-25

  • Closed date

    2025-11-19

  • Last modified date

    2026-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO05872 UO05873 UO05874

Modules/Macros

  • EZBTLCWK
    

Fix information

  • Fixed component name

    TCP/IP MVS

  • Fixed component ID

    5655HAL00

Applicable component levels

  • R250 PSY UO05872

       UP25/12/16 P F512 ¢

  • R310 PSY UO05873

       UP25/12/16 P F512 ¢

  • R320 PSY UO05874

       UP25/12/16 P F512 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: