IBM Support

PH67775: ON-DEMAND DEV AND TEST ENVIRONMENT 1.X: EXTRACTION FAILS WITH AN ABEND AND ERROR CODE 31324

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Test Accelerator for Z (TAZ): On-demand Dev and Test environment
    for z/OS 1.x
    
    After using OMPROUTE config to replace static TCP/IP BEGINROUTES
    
    definitions, Create Component process (i.e. extraction) fails
    with the
    following Abend error in the UI:
    
    Attention required
    
    An ABEND occurred on the IBM Z mainframe with the following
    output.
    .
    .
    Code: 31324
    
    The content of the ABEND shows SYSTEM COMPLETION CODE=0C4:
    
    /ABCDEF/usr/lpp/IBM/odtz > sfeuauth="AAAAA.BBBB.CCCCCCCC"
    _BPXK_JOBLOG=STDERR /usr/lpp/IBM/odtz/feuc jvollist
    10.15.12 STC29361  IEA995I SYMPTOM DUMP OUTPUT  841
    841             SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
    
    841              TIME=10.15.11  SEQ=00109  CPU=0000  ASID=019B
    841              PSW AT TIME OF ERROR  078D0000   C1D4C188  ILC
    6  INTC 11
    841                ACTIVE MODULE
    ADDRESS=00000000_41D4C000  OFFSET=00000188
    841                NAME=FEUSI002
    841                DATA AT PSW  41D4C182 - D2007010  5008D20F
    70145020
    841                AR/GR 0: 00000000/00000048   1:
    00000000/41E03EF8
    841                      2: 00000000/41D55000   3:
    00000000/41D421D8
    841                      4: 01FF000A/41D55040   5:
    00000000/41E03FF0
    841                      6: 00000000/FFFFDD01   7:
    00000000/41E03EF8
    841                      8: 00000000/00000024   9:
    00000000/00000001
    841                      A: 00000000/00000003   B:
    00000000/000101D8
    841                      C: 00000000/C1D4C000   D:
    00000000/41D420D0
    841                      E: 00000000/0000030B   F:
    00000000/00000000
    841              END OF SYMPTOM DUMP
    10.15.12 STC29361  BPXP018I THREAD 47AC300000000000, IN PROCESS
    67111741, ENDED  843
    843             WITHOUT BEING UNDUBBED WITH COMPLETION CODE
    940C4000
    843             , AND REASON CODE 00000011.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Customers creating components from a         *
    *                 Extracted type z/OS source system            *
    ****************************************************************
    * PROBLEM DESCRIPTION: OMPROUTE config causing ABEND 0C4       *
    ****************************************************************
    z/OS Extraction Utilities: Creating a component will fail with
    ABEND 0C4 if the user uses OMPROUTE config to replace static
    TCP/IP BEGINROUTES definitions
    

Problem conclusion

  • Creating component should be proceeding successfully
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH67775

  • Reported component name

    TEST ACCELERATO

  • Reported component ID

    5725G3923

  • Reported release

    F10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-08-17

  • Closed date

    2025-08-25

  • Last modified date

    2025-08-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO04612

Modules/Macros

  • FEU1SMPE FEU2RCVE FEU3ALOC FEU4ZFS  FEU5MKD  FEU6DDEF FEU7APLY
    FEU8ACPT FEUBLDT  FEUC     FEUCLI   FEUCLINF FEUCSTUB FEUCUTIL
    FEUCVOLI FEUCVPRM FEUDCAT  FEUDSL01 FEUDSL02 FEUDSS   FEUDSS1D
    FEUGSFTP FEUMKDIR FEUMOUNT FEURXDPJ FEURXDPL FEURXEXT FEUSI001
    FEUSI002 FEUVIMG  FEUXDDLP FEUXLOAD FEUXRDDL FEUXSQLP FEUXTBDT
    FEUXUNLD FEUXVERS FEUZCPT  FEUZLDFL FEUZSFTP
    

Fix information

  • Fixed component name

    Z/OS EXT UTILIT

  • Fixed component ID

    5725G3923

Applicable component levels

  • RF10 PSY UO04612

       UP25/08/30 P F508

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"F10"}]

Document Information

Modified date: