Error description
When z/OS Connect tracing is active and an API using the CICS service provider flows a channel with a container which contains no data, an ArrayOutOfBoundsException with the following message and traceback is reported: SRVE8025E: An error or timeout occured while doing async servlet processing. java.lang.ArrayIndexOutOfBoundsException at com.ibm.zosconnect.wv.TraceWriter.traceBuffer(Unknown Source) at com.ibm.zosconnect.WVDataXformImpl.getJSON(Unknown Source) at com.ibm.zosconnect.internal. ResponseDataHandler$ResponseDataImpl. setApplicationDataMap(Unknown Source) at com.ibm.zosconnect.service.cics.internal.CicsServiceImpl. invoke(Unknown Source) at com.ibm.zosconnect.internal.ZosConnectServiceImpl. apiInvoke(Unknown Source) at com.ibm.zosconnect.internal.ServiceManagerImpl.invoke(Unknown Source) The following message is also reported: BAQR7033E: Internal server error. Additional search words: SRVE8025E msgSRVE8025E SRVE8025 msgSRVE8025 BAQR7033E msgBAQR7033E BAQR7033 msgBAQR7033
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of the z/OS Connect V3.0 CICS * * service provider with OpenAPI 2 or OpenAPI 3 * * APIs, flowing containers with no data * * (zosconnect-2.0 and zosconnect-3.0). * **************************************************************** * PROBLEM DESCRIPTION: ArrayIndexOutOfBoundsException: Array * * index out of range: 0 followed by * * BAQR7033E: Internal server error. * **************************************************************** When tracing a CICS service provider API, which flowed a container with no data, the tracing code did not calculate the data to be traced correctly, which caused a java.lang.ArrayIndexOutOfBoundsException.
Problem conclusion
Temporary fix
Comments
z/OS Connect has been corrected to prevent the reported ArrayIndexOutOfBoundsException when tracing APIs which use the CICS service provider. The fix for this APAR is expected to be delivered by the PTF for z/OS Connect V3.0.99.0 (PH68482).
APAR Information
APAR number
PH67753
Reported component name
Z/OS CONNECT EE
Reported component ID
5655CE300
Reported release
000
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-08-14
Closed date
2025-10-17
Last modified date
2025-10-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
Z/OS CONNECT EE
Fixed component ID
5655CE300
Applicable component levels
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSVVFY","label":"z\/OS Connect Enterprise Edition"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"000"}]
Document Information
Modified date:
17 October 2025