A fix is available
APAR status
Closed as program error.
Error description
Migration to the 1.6.2 level may complete successfully, but Liberty fails to restart due to missing properties in the server.xml file. Migration might also fail as a result of a configuration failure. Additional keywords: DB2AIV1R6/K
Local fix
To work around the issue, run the deploy command again: a. Stop Db2ZAI b. From the $DB2ZAI_INSTALLATION/configuration/scripts directory, run: ./config.sh -a deploy Note: The values for each prompt are stored in the $DB2ZAI_HOME/config/config.json file and can be copy/pasted. c. Start Db2ZAI
Problem summary
**************************************************************** * USERS AFFECTED: All Db2 AI for z/OS (Db2ZAI) users who are * * migrating from prior Db2ZAI 1.6.0 * * maintenance levels to Db2ZAI 1.6.2. * **************************************************************** * PROBLEM DESCRIPTION: Migration to Db2ZAI 1.6.2 may fail or * * cause Liberty to not restart due to * * missing server.xml properties. * **************************************************************** * RECOMMENDATION: Apply corrective PTF when available * **************************************************************** Migration to the Db2ZAI 1.6.2 level may complete successfully, but Liberty fails to restart due to missing properties (jaasLoginContextEntry and jaasLoginModule) in the server.xml file.
Problem conclusion
This APAR resolves the issues described above. above. Additional keyword: DB2ZAIV1R6/K
Temporary fix
Comments
APAR Information
APAR number
PH67677
Reported component name
DB2 AI FOR Z/OS
Reported component ID
5698CGN00
Reported release
160
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-08-07
Closed date
2025-08-14
Last modified date
2025-08-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO04462
Modules/Macros
COYNOD02 COYREADM
Fix information
Fixed component name
DB2 AI FOR Z/OS
Fixed component ID
5698CGN00
Applicable component levels
R160 PSY UO04462
UP25/08/16 P F508
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"160"}]