Error description

  • **Problem Symptom**
    ABEND U0071 was repeated to all IMS TCBs when we started
    IMS 15.6 using ACBLIB.
    .
    **Introduction**
    When initiating IMS 15.6 using ACBLIB, we encountered
    an issue where an ABENDU0071 abend message was repeatedly
    generated across all IMS Task Control Blocks (TCBs).
    .
    **Background**
    The current mACB design for IMS V15.6 supports U0071 abends
    for the invalid parameter case, as introduced in PI86600.
    However, our analysis revealed that the same DFS629I
    messages with ABENDU0071 were repeated to all IMS TCBs,
    This indicates a potential issue with the error handling
    mechanism.
    .
    **Solution**
    This APAR request for the modification would help reduce
    the impact of the error and prevent unnecessary system
    downtime.
    .
    -----------------------------------------------------------
    <> The current state of affairs is as follows:
    DFS3505E SECTION=CATALOG  IS REQUIRED, PROCLIB MEMBER=DFSDF
    DFS629I IMS CTL TCB ABEND - IMS 0071
    DFS629I PSW AT ERROR = 077C1000 8BCDB45C
    DFS629I MODID = DFS3DF00+1510+20  EPA = 0BCDAC18
    DFS629I R0-3   0BD1C374 C4000047 00000000 00000001
    DFS629I R4-7   00001001 0BE44E00 0BCDC990 0000001C
    DFS629I R8-11  00C2A890 0BD1C038 00000000 0BD1C378
    DFS629I R12-15 0BCDC4C8 0BD1C038 8BCDB410 00001001
    IEA995I SYMPTOM DUMP OUTPUT  016
      USER COMPLETION CODE=0071 REASON CODE=00001001
     TIME=17.17.13  SEQ=00122  CPU=0000  ASID=002D
     PSW AT TIME OF ERROR  077C1000   8BCDB45C  ILC 2  INTC 0D
       NO ACTIVE MODULE FOUND
       NAME=UNKNOWN
       DATA AT PSW  0BCDB456 - 58F09344  0A0DA7F4  FF5B5820
       AR/GR 0: 007FB5F4/0BD1C374   1: 00000000/C4000047
             2: 00000000/00000000   3: 00000000/00000001
             4: 00000000/00001001   5: 00000000/0BE44E00
             6: 00000000/0BCDC990   7: 00000000/0000001C
             8: 00000000/00C2A890   9: 00000000/0BD1C038
             A: 00000000/00000000   B: 00000000/0BD1C378
             C: 00000000/0BCDC4C8   D: 00000000/0BD1C038
             E: 00000000/8BCDB410   F: 00000000/00001001
     END OF SYMPTOM DUMP
    DFS629I IMS STM TCB ABEND - IMS 0071
    DFS629I PSW AT ERROR = 077C1000 8BCDB45C
    DFS629I MODID = DFS3DF00+1510+20  EPA = 0BCDAC18
    DFS629I R0-3   0BD1C374 C4000047 00000000 00000001
    DFS629I R4-7   00001001 0BE44E00 0BCDC990 0000001C
    DFS629I R8-11  00C2A890 0BD1C038 00000000 0BD1C378
    DFS629I R12-15 0BCDC4C8 0BD1C038 8BCDB410 00001001
    ::: omit ::::
    *** U0071 mesage appears in all IMS CTL jobstep TCBs ***
    ::: omit ::::
    DFS629I IMS DLG TCB ABEND - IMS 0071
    DFS629I PSW AT ERROR = 077C1000 8BCDB45C
    DFS629I MODID = DFS3DF00+1510+20  EPA = 0BCDAC18
    DFS629I R0-3   0BD1C374 C4000047 00000000 00000001
    DFS629I R4-7   00001001 0BE44E00 0BCDC990 0000001C
    DFS629I R8-11  00C2A890 0BD1C038 00000000 0BD1C378
    DFS629I R12-15 0BCDC4C8 0BD1C038 8BCDB410 00001001
    DFS627I IMS RTM CLEANUP ( EOT ) COMPLETE FOR JS
    .
    
    <> The requested fix is as follows:
    DFS3505E SECTION=CATALOG  IS REQUIRED, PROCLIB MEMBER=DFSDF
    DFS629I IMS CTL TCB ABEND - IMS 0071
    DFS629I PSW AT ERROR = 077C1000 8BD1645C
    DFS629I MODID = DFS3DF00+1510+20  EPA = 0BD15C18
    DFS629I R0-3   0BD1D374 84000047 00000000 00000001
    DFS629I R4-7   00001001 0BE44E00 0BD17990 0000001C
    DFS629I R8-11  00C2A890 0BD1D038 00000000 0BD1D378
    DFS629I R12-15 0BD174C8 0BD1D038 8BD16410 00001001
    IEA995I SYMPTOM DUMP OUTPUT  728
      USER COMPLETION CODE=0071 REASON CODE=00001001
     TIME=11.44.17  SEQ=00211  CPU=0000  ASID=002D
     PSW AT TIME OF ERROR  077C1000   8BD1645C  ILC 2  INTC 0D
       NO ACTIVE MODULE FOUND
       NAME=UNKNOWN
       DATA AT PSW  0BD16456 - 58F09344  0A0DA7F4  FF5B5820
       AR/GR 0: 007FB5F4/0BD1D374   1: 00000000/84000047
             2: 00000000/00000000   3: 00000000/00000001
             4: 00000000/00001001   5: 00000000/0BE44E00
             6: 00000000/0BD17990   7: 00000000/0000001C
             8: 00000000/00C2A890   9: 00000000/0BD1D038
             A: 00000000/00000000   B: 00000000/0BD1D378
             C: 00000000/0BD174C8   D: 00000000/0BD1D038
             E: 00000000/8BD16410   F: 00000000/00001001
     END OF SYMPTOM DUMP
    DFS629I IMS RDS TCB ABEND - IMS 4095
    DFS629I IMS XFP TCB ABEND - IMS 4095
    DFS629I IMS FP2 TCB ABEND - IMS 4095
    DFS629I IMS STC TCB ABEND - IMS 4095
    DFS629I IMS RST TCB ABEND - IMS 4095
    DFS629I IMS DYA TCB ABEND - IMS 4095
    DFS629I IMS DLI TCB ABEND - IMS 4095
    DFS629I IMS DCC TCB ABEND - IMS 4095
    DFS629I IMS TRA TCB ABEND - IMS 4095
    DFS629I IMS CTX TCB ABEND - IMS 4095
    DFS629I IMS TMC TCB ABEND - IMS 4095
    DFS629I IMS LUM TCB ABEND - IMS 4095
    DFS629I IMS OII TCB ABEND - IMS 4095
    DFS629I IMS OIC TCB ABEND - IMS 4095
    DFS629I IMS RCF TCB ABEND - IMS 4095
    DFS629I IMS RWM TCB ABEND - IMS 4095
    DFS629I IMS WTR TCB ABEND - IMS 4095
    DFS629I IMS DGS TCB ABEND - IMS 4095
    DFS629I IMS DYD TCB ABEND - IMS 4095
    DFS629I IMS RLM TCB ABEND - IMS 4095
    DFS629I IMS RRS TCB ABEND - IMS 4095
    DFS629I IMS ALC TCB ABEND - IMS 4095
    DFS629I IMS XCF TCB ABEND - IMS 4095
    DFS629I IMS ALM TCB ABEND - IMS 4095
    DFS629I IMS RLM TCB ABEND - IMS 4095
    DFS629I IMS DLG TCB ABEND - IMS 4095
    DFS629I IMS STM TCB ABEND - IMS 4095
    DFS627I IMS RTM CLEANUP ( EOT ) COMPLETE FOR JS
    .
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All IMS V15 users of the IMS Catalog.                        *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Repeated IMS ABENDU0071s complicate diagnostics.             *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * INSTALL CORRECTIVE SERVICE FOR APAR/PTF.                     *
    ****************************************************************
    During IMS catalog initialization, misconfigured CATALOG and
    ACBMGMT parameters in the CATALOG and CATALOGxxxx sections of
    the DFSDFxxx member of the IMS.PROCLIB data set lead to error
    message MSGDFS3505E and multiple ABENDU0071s. These abends
    propagate across all TCBs in the control region because the
    ABEND macro call includes the STEP parameter, which terminates
    the entire job step instead of isolating the failure to the
    affected TCB.
    

Problem conclusion

  • DFS3DF00 Online IMS catalog initialization: Removed the STEP
    parameter in the ABEND macro calls to terminate only the active
    task, rather than the entire job step.
    
    IMSMGDACBS/K
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH67671

  • Reported component name

    IMS V15

  • Reported component ID

    5635A0600

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-08-06

  • Closed date

    2025-09-04

  • Last modified date

    2025-10-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO04770

Modules/Macros

  • DFS3DF00
    

Fix information

  • Fixed component name

    IMS V15

  • Fixed component ID

    5635A0600

Applicable component levels

  • R500 PSY UO04770

       UP25/09/06 P F509

Fix is available