Error description

  • At CICS TS 6.1 and below, DFHDTSVC is downward compatible, and
    it is shipped in SDFHLINK. At CICS TS 6.1 and below, when there
    are multiple releases of CICS in the same LPAR, it makes sense
    to put the highest release of SDFHLINK in LNKLST or LPA.  All
    releases of CICS could then use highest version of DFHDTSVC.
    Starting with CICS TS 6.2, that is no longer the case.
    
    CICS TS 6.2 makes a change to DFHDTSVC that makes it no longer
    downward compatible with prior releases.  As such, CICS TS 6.2
    ships DFHDTSVC in SDFHAUTH.   Prior releases of CICS should not
    use the CICS TS 6.2 version of DFHDTSVC.
    
    If a CICS TS 6.1 (or lower) CICS region loads and uses a CICS TS
    6.2 (or higher) version of DFHDTSVC, Data Tables accesses still
    work, but they do not work efficiently.   Read requests do not
    access the loaded data table directly.   All requests, including
    Reads, are function shipped to the owning FOR.  This causes lots
    more CSMI tasks in the FOR, and more overall CPU used.  There is
    no message warning that a CICS TS 6.1 (or lower) CICS region is
    incorrectly using a CICS TS 6.2 (or higher) version of DFHDTSVC.
    
    
    There needs to be a message warning of this mistake.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: When planning to upgrade to CICS TS 6.2 *
    *                      or higher, remote file control requests *
    *                      against Data Table files will be        *
    *                      function shipped if the wrong version   *
    *                      of DFHDTSVC is used.                    *
    ****************************************************************
    Prior to CICS TS 6.2, DFHDTSVC was backwards compatible for
    upgrade purposes and was stored in the LPA. Due to the changes
    made in CICS TS 6.2, DFHDTSVC was moved to the SDFHAUTH library
    so it would not be used by lower level versions of CICS when
    upgrade planning.
    
    If the CICS TS 6.2 SDFHAUTH library is placed in the DFHRPL
    concatenation before the lower level CICS's SDFHLINK library,
    then the lower level CICS release will use the CICS TS 6.2
    version of DFHDTSVC.
    
    The consequence of this is that all remote data table file
    control requests will be function shipped to the FOR rather
    than taking advantage of Data Table Services.
    

Problem conclusion

  • DFHFCDTS has been altered to issue new error message
    DFHFC0432 to state that the wrong version of DFHDTSVC is being
    used by CICS TS and that all remote data table file control
    requests will be function shipped.
    
    New Message DFHFC0432 has been added to the CICS TS for z/OS 5.6
    Documentation site.
    
    DFHFC04032 E applid Shared access to remote data tables cannot
    be provided by this CICS system because the version of DFHDTSVC
    being used is incompatible with this release.
    
    Explanation
    CICS is about to issue a file control request against a remote
    data table but cannot do so because the version of DFHDTSVC
    being used is incompatible with this release.  This will prevent
    this CICS system being able to access the data table using
    cross memory services, so the file control request will be
    function shipped.
    
    System Action
    Processing continues with remote data table file control
    requests being function shipped. This will result in a
    performance degradation.
    
    Message DFHFC0432 will be reissued if any subsequent request is
    made to read or browse a remote data table. However, message
    DFHFC0432 is not issued more often than once an hour.
    
    User Response
    The CICS system should be pointed at the correct version of
    DFHDTSVC. DFHDTSVC supplied with CICS TS V6.2 is not backwards
    compatible.
    
    Module
    DFHFCDTS
    
    XMEOUT parameters/Message inserts
    1. applid
    
    Destination
    Console
    
    Applicable releases
    5.6
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH67553

  • Reported component name

    CICS TS Z/OS V5

  • Reported component ID

    5655Y0400

  • Reported release

    300

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-07-29

  • Closed date

    2026-07-30

  • Last modified date

    2026-07-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH69960 UO08824

Modules/Macros

  • DFHAMFC  DFHAMPFI DFHAPSM  DFHAPTR5 DFHBRNS  DFHDMPCA DFHDMRM
    DFHDTLA  DFHDTLX  DFHEDFX  DFHEIFC  DFHEIQCF DFHEIQDN DFHEIQDS
    DFHEIQMS DFHEIQSA DFHEIUOW DFHESE   DFHFCAT  DFHFCBD  DFHFCBU
    DFHFCCA  DFHFCDL  DFHFCDN  DFHFCDO  DFHFCDR  DFHFCDTS DFHFCDTX
    DFHFCDU  DFHFCDUF DFHFCDW  DFHFCDY  DFHFCES  DFHFCFL  DFHFCFR
    DFHFCFS  DFHFCIN1 DFHFCIN2 DFHFCIR  DFHFCL   DFHFCLF  DFHFCLJ
    DFHFCLJ1 DFHFCM   DFHFCMT  DFHFCN   DFHFCNQ  DFHFCOR  DFHFCQI
    DFHFCQR  DFHFCQS  DFHFCQT  DFHFCQU  DFHFCQX  DFHFCRC  DFHFCRC2
    DFHFCRD  DFHFCRF  DFHFCRL  DFHFCRN  DFHFCRO  DFHFCRP  DFHFCRR
    DFHFCRS  DFHFCRV  DFHFCSD  DFHFCSDS DFHFCST  DFHFCU   DFHFCVC
    DFHFCVR  DFHFCVS  DFHFCXDF DFHFRDUF DFHISFS  DFHMEFAC DFHMEFAE
    DFHMEFAK DFHMIRS  DFHSTFC  DFHSTLS  DFHSTP   DFHW2FI  DFHW2FR
    DFHXFP   DFHXFQ   DFHXFRM  DFHXFX
    

Fix information

  • Fixed component name

    CICS TS Z/OS V5

  • Fixed component ID

    5655Y0400

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.6","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date:
30 July 2026