Error description
Error Message: N/A . Stack Trace: N/A . IFASMFDL (the SMF log stream dump program) fails to retrieve SMF records written by JZOS ZUtil.smfRecord() when filtering by date. The JZOS ZUtil.smfRecord() API writes SMF records with an incorrect sign character in the packed format value of the date field.
Local fix
Problem summary
The issue occurs when JZOS records the date information in the SMF 121 record with an incorrect last nibble value. The last nibble is expected to be 'F'; if it is not, any program that validates this nibble may fail to correctly interpret or retrieve the SMF 121 data.
Problem conclusion
JZOS has been updated to correctly generate the final nibble in the date field of the SMF 121 record, ensuring it is set to the expected value of 'F'. . This APAR will be fixed in the following Releases: . IBM Semeru Runtimes 21 21.0.8.0 17 17.0.16.0 11 11.0.28.0 IBM SDK, Java Technology Edition 8 SR8 FP55 (8.0.8.55) . Downloads and supplementary documentation can be found at the following locations: - For the z/OS operating system: - Java SDK Products on z/OS https://www.ibm.com/support/pages/java-sdk-products-zos
Temporary fix
Comments
APAR Information
APAR number
PH67057
Reported component name
JAVA Z/OS 64
Reported component ID
620700104
Reported release
H00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-06-21
Closed date
2025-07-01
Last modified date
2025-07-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
JAVA Z/OS 64
Fixed component ID
620700104
Applicable component levels
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"H00","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date:
02 July 2025