IBM Support

PH67049: ABEND0C4 OCCURS IN FABYITK0

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • ABEND0C4 occurs in FABYITK0 (CSECT: FABYIT10) when all the
    following conditions are met:
    
    
    
    - OPRTLP=YES or OPRTLC=YES is specified in the FABYIN input
    stream.
    - The "LISTING OF ORPHAN RECORDS" report has 655,360 lines or
    more.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of IMS High Performance Prefix     *
    *                 Resolution for z/OS Version 3 Release 1      *
    *                 (FMID=H1IP310).                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: ABEND0C4 occurs in FABYITK0             *
    ****************************************************************
    ABEND0C4 occurs in FABYITK0 (CSECT: FABYIT10) when all the
    following conditions are met:
    
    - OPRTLP=YES or OPRTLC=YES is specified in the FABYIN input
      stream.
    - The "LISTING OF ORPHAN RECORDS" report has 655,360 lines or
      more.
    

Problem conclusion

  • HPPR has been modified to prevent overflow of the field that
    stores the number of rows in a report.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH67049

  • Reported component name

    IMS HP PREFIX R

  • Reported component ID

    5655I1500

  • Reported release

    310

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-06-20

  • Closed date

    2025-07-04

  • Last modified date

    2025-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO03961

Modules/Macros

  • FABYIT10
    

Fix information

  • Fixed component name

    IMS HP PREFIX R

  • Fixed component ID

    5655I1500

Applicable component levels

  • R310 PSY UO03961

       UP25/07/05 P F507

Fix is available