A fix is available
APAR status
Closed as program error.
Error description
ABEND0C4 occurs in FABYITK0 (CSECT: FABYIT10) when all the following conditions are met: - OPRTLP=YES or OPRTLC=YES is specified in the FABYIN input stream. - The "LISTING OF ORPHAN RECORDS" report has 655,360 lines or more.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users of IMS High Performance Prefix * * Resolution for z/OS Version 3 Release 1 * * (FMID=H1IP310). * **************************************************************** * PROBLEM DESCRIPTION: ABEND0C4 occurs in FABYITK0 * **************************************************************** ABEND0C4 occurs in FABYITK0 (CSECT: FABYIT10) when all the following conditions are met: - OPRTLP=YES or OPRTLC=YES is specified in the FABYIN input stream. - The "LISTING OF ORPHAN RECORDS" report has 655,360 lines or more.
Problem conclusion
HPPR has been modified to prevent overflow of the field that stores the number of rows in a report.
Temporary fix
Comments
APAR Information
APAR number
PH67049
Reported component name
IMS HP PREFIX R
Reported component ID
5655I1500
Reported release
310
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-06-20
Closed date
2025-07-04
Last modified date
2025-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO03961
Modules/Macros
FABYIT10
Fix information
Fixed component name
IMS HP PREFIX R
Fixed component ID
5655I1500
Applicable component levels
R310 PSY UO03961
UP25/07/05 P F507
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCX89H","label":"IMS Tools"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"310"}]
Document Information
Modified date:
02 August 2025