Error description

  • In CICS v6.1, some DFHMQ* messages were updated to include the
    name of the MQMONITOR in the message text if an MQMONITOR is
    associated with the CICS-MQ bridge that issued the error for the
    call. If there is not an MQMONITOR associated with the call,
    then a 4th insert may not be passed to the Message domain. In
    this case, DFHMEBU issues a DFHME0111 message:
    
    09.58.00 STC95732  +DFHME0111 CICSREGN Insert number 04 is
    missing for message DFHMQ0704
    .
    
    
    Additional Keyword(s): MEBU, MQMON
    
    KIXREVACC
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Users.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Message DFHME0111 issued following      *
    *                      DFHMQ0704.                              *
    ****************************************************************
    A CICS region running with MQMonitors may see message DFHME0111
    being issued following a message DFHMQ0704 indicating that
    this message is missing an insert, the 4th one, which should be
    the name of an MQMonitor.
    

Problem conclusion

  • DFHMQBR0 has been changed to add the MQMonitor name to message
    insert 4 for DFHMQ0704.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH66826

  • Reported component name

    CICS TS Z/OS V6

  • Reported component ID

    5655YA100

  • Reported release

    400

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-06-03

  • Closed date

    2025-08-19

  • Last modified date

    2025-08-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO04540 UO04541

Modules/Macros

  • DFHMQBID DFHMQCM@ DFHMQP0@ DFHMQP1@ DFHMQP3@ DFHMQR0@
    

Fix information

  • Fixed component name

    CICS TS Z/OS V6

  • Fixed component ID

    5655YA100

Applicable component levels

  • R400 PSY UO04541

       UP25/08/20 P F508

  • R500 PSY UO04540

       UP25/08/20 P F508

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB70","label":"Z TPS"}}]

Document Information

Modified date:
31 August 2025