A fix is available
APAR status
Closed as program error.
Error description
When a RBA/LRSN is specified for RECOVER of a partitioned object, Automation Expert must search backwards from that specified RBA/LRSN to find a starting point with which to begin the recovery. If a PART ALL IC is found in SYSCOPY - but is not usable (perhaps the underlying DSN was deleted) Automation Expert needs to continue searching backwards for other recovery points from which to begin. Also, it could be that a PART ALL IC does NOT exist. Automation Expert code needs to look for PART-level( n ) ICs to optimize how a recovery starting point is identified. This PTF will optimize Automation Experts recovery efforts for the instances described above to look for PART-level( n ) image copy DSNs and use those (if found) as a starting point for recovery
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All Users. * **************************************************************** * PROBLEM DESCRIPTION: When a RBA/LRSN is specified for * * RECOVER of a partitioned object, * * Automation Expert must search backwards * * from that specified RBA/LRSN to find a * * starting point with which to begin the * * recovery. If a PART ALL IC is found in * * SYSCOPY - but is not usable (perhaps * * the underlying DSN was deleted) * * Automation Expert needs to continue * * searching backwards for other recovery * * points from which to begin. * * * * Also, it could be that a PART ALL IC * * does NOT exist. Automation Expert code * * needs to look for PART-level( n ) ICs * * to optimize how a recovery starting * * point is identified. This PTF will * * optimize Automation Experts recovery * * efforts for the instances described * * above to look for PART-level( n ) image * * copy DSNs and use those (if found) as a * * starting point for recovery * **************************************************************** * RECOMMENDATION: APPLY the PTF * **************************************************************** .
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PH66620
Reported component name
AUTOMATION EXPE
Reported component ID
5698DAE00
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-05-20
Closed date
2026-02-02
Last modified date
2026-02-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UO06660
Modules/Macros
DAJ#SCPY DAJRBLDJ DAJRCVRJ
Fix information
Fixed component name
AUTOMATION EXPE
Fixed component ID
5698DAE00
Applicable component levels
R110 PSY UO06660
UP26/02/04 I 1000
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.