APAR status
Closed as program error.
Error description
The queue handle for the MQInput node is not expected to be released, even when the sharedConnectorIdleTimeout property is set. However, setting the sharedConnectorIdleTimeout value to less than 5 seconds causes the queue handle to close when the flow is idle.
Local fix
NA
Problem summary
**************************************************************** USERS AFFECTED: All users of IBM App Connect Enterprise V12.0 and V13.0 and IBM Integration Bus V10.1 using the MQInput node. Platforms affected: WinX64, LinuxX64, LinuxZ64, AIX, LinuxPPCLE64, ZOS **************************************************************** PROBLEM DESCRIPTION: The queue handle for the MQInput node is not expected to be released, even when the sharedConnectorIdleTimeout property is set. However, setting the sharedConnectorIdleTimeout value to less than 5 seconds causes the queue handle to close when the flow is idle.
Problem conclusion
The product no longer closes the Queue Handle associated with the MQInput node when the flow is idle. --------------------------------------------------------------- The fix is targeted for delivery in the following PTFs: Version Maintenance Level v10.1 10.1.0.6 v12.0 12.0.12.17 v13.0 13.0.5.0 The latest available maintenance can be obtained from: http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041 If the maintenance level is not yet available,information on its planned availability can be found on: http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308 ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
PH66587
Reported component name
INT BUS FOR Z/O
Reported component ID
5655AB110
Reported release
A10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2025-05-19
Closed date
2025-07-23
Last modified date
2025-07-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INT BUS FOR Z/O
Fixed component ID
5655AB110
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSNQH8","label":"IBM Integration Bus for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A10","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]
Document Information
Modified date:
23 July 2025