PH66450: COMPONENT CREATION / EXTRACTION OF SYSRES VOLUME FAILS WITH RETURN CODE 1, ERROR CODE 31061

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IBM Z Development and Test Environment (ZD&T) 14.x.x
    IBM Virtual Dev and Test for z/OS (ZVDT) 1.x
    Wazi Image Builder (WIB) 2.x
    Test Accelerator for Z (TAZ): On-demand Dev and Test environment
    for z/OS 1.x
    .
    During the Create Component process of a SYSRES VOLUME, if the
    IPADDR definition contains the CIDR notation (e.g. 10.2.2.2/24),
    
    the extraction will fail with the following error output to the
    UI:
    
    Attention required
    Running the z/OS Configure Generating Tool command failed with
    return code 1
    
    Cause: A message returned...
    .
    ..
    Failed to inject symbol(s) &HOMEIPADDRESS1 in any target
    profile(s).
    
    Code: 31061
    

Local fix

  • Remove the CIDR subnet mask from the IPADDR definition in the
    TCP/IP profile member (e.g. '/24') and re-extract the component.
    
    Once successful, restore the CIDE subnet mask in the IPADDR
    definition in the TCP/IP profile member.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: 1.Customers creating SYSRES components.      *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1.TCP/IP profile containing mask could  *
    *                       cause failure.                         *
    ****************************************************************
    1.During the Create Component process of a SYSRES VOLUME, if the
      IPADDR definition contains the CIDR notation
      (e.g. 10.2.2.2/24), the extraction will fail with the
      following error output to the UI:
      Attention required
      Running the z/OS Configure Generating Tool command failed with
      return code 1
      Cause: A message returned...
      ...
      Failed to inject symbol(s) &HOMEIPADDRESS1 in any target
      profile(s).
      Code: 31061
      Problem Conclusion:
      Creating SYSRES components with such TCP/IP profile won't
      fail because of the IP address mask.
    

Problem conclusion

  • 1.Code is updated to handle the issue.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH66450

  • Reported component name

    Z/OS EXT UTILIT

  • Reported component ID

    5725G3923

  • Reported release

    F10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2025-05-07

  • Closed date

    2025-11-24

  • Last modified date

    2025-11-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UO05944

Modules/Macros

  • FEU1SMPE FEU2RCVE FEU3ALOC FEU4ZFS  FEU5MKD  FEU6DDEF FEU7APLY
    FEU8ACPT FEUBLDT  FEUC     FEUCLI   FEUCLINF FEUCSTUB FEUCUTIL
    FEUCVOLI FEUCVPRM FEUDCAT  FEUDSL01 FEUDSL02 FEUDSS   FEUDSS1D
    FEUGSFTP FEUMKDIR FEUMOUNT FEURXDPJ FEURXDPL FEURXEXT FEUSI001
    FEUSI002 FEUVIMG  FEUXDDLP FEUXLOAD FEUXRDDL FEUXSQLP FEUXTBDT
    FEUXUNLD FEUXVERS FEUZCPT  FEUZLDFL FEUZSFTP
    

Fix information

  • Fixed component name

    Z/OS EXT UTILIT

  • Fixed component ID

    5725G3923

Applicable component levels

  • RF10 PSY UO05944

       UP25/11/26 P F511

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU011","label":"Systems - zSystems software"},"Product":{"code":"SG19M"},"Platform":[{"code":"PF054","label":"z Systems"}],"Version":"F10"}]

Document Information

Modified date:
30 November 2025